Home › Drivetrain › U660F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSAXLE SYSTEM › 2013.12–2016.11
RM3160E _52 Drivetrain _019726 U660F AUTOMATIC TRANSMISSION / TRANSAXLE _0109808 AUTOMATIC TRANSAXLE SYSTEM C

U660F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P2810  Pressure Control Solenoid "G" Electrical (Shift Solenoid Valve SL4)  


DESCRIPTION

Changing from 1st to 6th is performed by the TCM turning shift solenoid valves SL1, SL2, SL3, SL4 and SL on and off. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated.

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2810 Pressure Control Solenoid "G" Electrical (Shift Solenoid Valve SL4) An open or short circuit (output signal duty is 0% or 100%) is detected by the TCM in the shift solenoid valve SL4 circuit while driving and shifting gears (SL4 output signal duty is more than 0% and less than 100% under normal conditions) (1-trip detection logic).
·

Open or short in shift solenoid valve SL4 circuit

·

Shift solenoid valve SL4

·

TCM


Comes on DTC stored

MONITOR DESCRIPTION

The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores a DTC. The TCM also performs the fail-safe function and turns the other normal shift solenoid valves on or off (in case of an open or short circuit, the TCM stops sending current to the circuit).

Click hereDrivetrain>U660F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSAXLE SYSTEM>FAIL-SAFE CHART

WIRING DIAGRAM

C133261
5.604,4.51 6.229,4.729 0.625,0.219 10 TCM 1.99,3.844 3.365,4.271 1.375,0.427 10 Transaxle Assembly 5.094,1.844 5.635,2.01 0.542,0.167 10 SL4+ 5.865,1.094 6.406,1.26 0.542,0.167 10 +B 5.094,3.229 5.635,3.396 0.542,0.167 10 SL4- 1.604,2.344 3.656,2.729 2.052,0.385 10 Shift Solenoid Valve SL4

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SL4)
a.
C133212
1.417,1.135 2.219,1.302 false 1.531,1.031 2.333,0.823 false 2.271,1.24 2.625,1.385 0.354,0.146 10 SL4+ 2.375,0.729 2.708,0.875 0.333,0.146 10 SL4- 0.656,0.313 0.99,0.458 0.333,0.146 10 *a
*a Component without harness connected
(Transmission Wire)


Remove the TCM from the transaxle.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
22 (SL4+) - 21 (SL4-) 20°C (68°F) 5.0 to 5.6 Ω
22 (SL4+) - Body ground and other terminals Always 10 kΩ or higher
21 (SL4-) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

2.INSPECT SHIFT SOLENOID VALVE SL4
2.INSPECT SHIFT SOLENOID VALVE SL4
a.
C201747C02
1.49,0.875 0.635,0.646 false 1.781,0.865 2.479,0.625 false 1.49,3.125 0.635,2.896 false 1.781,3.125 2.479,2.885 false 0.49,0.521 0.667,0.719 0.177,0.198 10 1 2.531,0.5 2.708,0.698 0.177,0.198 10 2 1.177,4.198 1.385,4.406 0.208,0.208 10 (-) 1.917,4.208 2.146,4.406 0.229,0.198 10 (+) 0.51,2.771 0.688,2.969 0.177,0.198 10 1 2.521,2.76 2.698,2.958 0.177,0.198 10 2 0.135,0.135 0.354,0.344 0.219,0.208 10 *1
*1 Shift Solenoid Valve SL4


Remove shift solenoid valve SL4.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

OK:

Valve moves and makes an operating sound.



Result:
Proceed to
OK
NG



OK

NG