Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM3160E _58 Vehicle Interior _019714 HEATING / AIR CONDITIONING _0109951 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) U

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  DATA LIST / ACTIVE TEST  


DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler (room temp. sensor) thermistor Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed -
Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed -
Adjusted Ambient Temp Adjusted ambient temperature Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F)
- -
Evaporator Fin Thermistor No. 1 cooler thermistor Min.: -30.00°C (-22.00°F)
Max.: 59.60°C (139.28°F)
Actual evaporator temperature displayed -
Evaporator Target Temp Evaporator target temperature Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Evaporator target temperature displayed -
Solar Sensor (D Side) Driver side automatic light control sensor Min.: 0
Max.: 255
Driver side automatic light control sensor value increases as brightness increases -
Solar Sensor (P Side) Front passenger side automatic light control sensor Min.: 0
Max.: 255
Front passenger side automatic light control sensor value increases as brightness increases -
Engine Coolant Temp Engine coolant temperature sensor Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F)
Actual engine coolant temperature displayed -
Blower Motor Speed Level Blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases between 0 and 31 as blower motor speed increases -
Regulator Pressure Sensor Air conditioner tube and accessory assembly Min.: -456.6 kPaG
Max.: 3294.3 kPaG
Actual refrigerant pressure displayed -
Regulator Control Current Solenoid valve control current Min.: 0 A
Max.: 0.997 A
Displayed value changes between 0 A and 0.997 A in accordance with solenoid valve operation -
Room Temp Sensor (Rear) Cooler (No. 2 room temp. sensor) thermistor Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual rear cabin temperature displayed -
Evap Temp Sensor (Rear) Rear evaporator temperature sensor Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual rear evaporator temperature displayed -
Blower Motor Level (Rear) Rear blower motor speed level Min.: 0
Max.: 31
Displayed speed level increases between 0 and 31 as rear blower motor speed increases -
Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (air mix for driver side)*2 or No. 1 air conditioning radiator damper servo sub-assembly (air mix for driver side)*3 target pulse Min.: 128
Max.: 383
for LHD
·

MAX COLD: 5 (pulse)

·

MAX HOT: 103 (pulse)


for RHD
·

MAX COLD: 105 (pulse)

·

MAX HOT: 7 (pulse)


-
Air Mix Servo Actual Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (air mix for driver side)*2 or No. 1 air conditioning radiator damper servo sub-assembly (air mix for driver side)*3 actual pulse Min.: 128
Max.: 383
for LHD
·

MAX COLD: 5 (pulse)

·

MAX HOT: 103 (pulse)


for RHD
·

MAX COLD: 105 (pulse)

·

MAX HOT: 7 (pulse)


-
Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*2 or No. 2 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*3 target pulse Min.: 128
Max.: 383
for LHD
·

MAX COLD: 105 (pulse)

·

MAX HOT: 7 (pulse)


for RHD
·

MAX COLD: 5 (pulse)

·

MAX HOT: 103 (pulse)


-
Air Mix Servo Actual Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*2 or No. 2 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*3 actual pulse Min.: 128
Max.: 383
for LHD
·

MAX COLD: 105 (pulse)

·

MAX HOT: 7 (pulse)


for RHD
·

MAX COLD: 5 (pulse)

·

MAX HOT: 103 (pulse)


-
Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) target pulse Min.: 128
Max.: 383
·

FACE: 8 (pulse)

·

B/L: 30 (pulse)

·

FOOT: 74 (pulse)

·

FOOT/DEF: 80 (pulse)

·

DEF: 97 (pulse)


-
Air Outlet Servo Actu Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse Min.: 128
Max.: 383
·

FACE: 8 (pulse)

·

B/L: 30 (pulse)

·

FOOT: 74 (pulse)

·

FOOT/DEF: 80 (pulse)

·

DEF: 97 (pulse)


-
Air Inlet Damper Targ Pulse Blower damper servo sub-assembly (air inlet) target pulse Min.: 128
Max.: 383
·

Recirculation: 7 (pulse)

·

Fresh: 28 (pulse)


-
Air Inlet Damper Actual Pulse Blower damper servo sub-assembly (air inlet) actual pulse Min.: 128
Max.: 383
·

Recirculation: 7 (pulse)

·

Fresh: 28 (pulse)


-
Electric Heater Count Maximum quick heater operation level Min.: 0
Max.: 3
Maximum possible operation of quick heater displayed *1
Electric Heater Active Level Actual quick heater operation level Min.: 0
Max.: 3
Actual operation level of quick heater displayed *1
Shift Set Temperature Shift set temperature 2C decr, 1C decr, Normal, 1C incr, 2C incr Customized value displayed -
Air Inlet Mode Air inlet mode Auto or Manual Customized value displayed -
Compressor Mode Compressor mode Auto or Manual Customized value displayed -
Evaporator Control Evaporator control Auto or Manual Customized value displayed -
Add Foot Air in FACE Mode Add foot air in face mode ON or OFF Customized value displayed -
Refrigerant Shortage Check Refrigerant shortage check ON or OFF Customized value displayed -
Fan speed increment control Fan speed increment control Slow, Normal, Fast Customized value displayed -
Foot/DEF Auto Mode Foot/defroster auto mode ON or OFF Customized value displayed -
Foot/DEF Auto Blow Up Foot/defroster auto blower speed increase ON or OFF Customized value displayed -
Ambient Temperature Shift Ambient temperature shift 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr Customized value displayed -
Air Mix Servo Targ Pls(F&R D) Rear air mix damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

MAX COLD: 9 (pulse)

·

MAX HOT: 54 (pulse)


-
A/M Servo Actual Pulse(F&R D) Rear air mix damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

MAX COLD: 9 (pulse)

·

MAX HOT: 54 (pulse)


-
Air Outlet Servo Pls (F&R D) Rear mode damper servo sub-assembly target pulse Min.: 128
Max.: 383
·

FACE: 83 (pulse)

·

B/L: 38 (pulse)

·

FOOT: 7 (pulse)


-
A/O Servo Actual Pulse(F&R D) Rear mode damper servo sub-assembly actual pulse Min.: 128
Max.: 383
·

FACE: 83 (pulse)

·

B/L: 38 (pulse)

·

FOOT: 7 (pulse)


-
A/C Cutoff Signal Air conditioning control cutoff signal OFF or ON The ECM sends the air conditioning control cutoff signal displayed -
Refrigerant Gas Type Refrigerant gas type R134a or 1234yf Refrigerant gas type displayed -
Set Temperature (D Side) Driver side set temperature Min.: MAX COLD
Max.: MAX HOT
Driver side set temperature displayed -
Set Temperature (P Side) Front passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Front passenger side set temperature displayed -
Set Temperature (Rear) Rear passenger side set temperature Min.: MAX COLD
Max.: MAX HOT
Rear passenger side set temperature displayed -
Number of Trouble Codes Number of trouble codes Min.: 0
Max.: 255
Number of DTCs displayed -

*1: w/ PTC Heater

*2: for LHD

*3: for RHD




ACTIVE TEST


HINT:

Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Blower Motor Blower motor with fan sub-assembly Min.: 0
Max.: 31
-
Magnetic Clutch Relay Air conditioning system operation OFF or ON -
Defogger Relay (Rear) Rear window defogger OFF or ON -
Deicer Relay (Front) Windshield deicer OFF or ON *2
Heater Active Level Quick heater assembly Min.: 0
Max.: 3
*1
Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (air mix for driver side)*3 or No. 1 air conditioning radiator damper servo sub-assembly (air mix for driver side)*4 pulse Min.: 128
Max.: 383
for LHD:

Operates between 5 to 103 pulses


for RHD:

Operates between 7 to 105 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*3 or No. 2 air conditioning radiator damper servo sub-assembly (air mix for front passenger side)*4 pulse Min.: 128
Max.: 383
for LHD:

Operates between 7 to 105 pulses


for RHD:

Operates between 5 to 103 pulses


Air Outlet Servo Pulse (D) No. 1 air conditioning radiator damper servo sub-assembly (air outlet) pulse Min.: 128
Max.: 383
Operates between 8 to 97 pulses
Air Inlet Damper Targ Pulse Blower damper servo sub-assembly (air inlet) pulse Min.: 128
Max.: 383
Operates between 7 to 28 pulses
Rear Blower Motor Rear blower motor with fan sub-assembly Min.: 0
Max.: 31
-
A/M Servo Pulse(F&R D) Rear air mix damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 9 to 54 pulses
A/O Servo Pulse(F&R D) Rear mode damper servo sub-assembly pulse Min.: 128
Max.: 383
Operates between 7 to 83 pulses

*1: w/ PTC Heater

*2: w/ Windshield Deicer System

*3: for LHD

*4: for RHD