Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)
RM3160E _58 Vehicle Interior _019714 HEATING / AIR CONDITIONING _0109951 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1419/19  Rear Room Temperature Sensor Circuit  


DESCRIPTION

The cooler (No. 2 room temp. sensor) thermistor is installed in the rear panel to detect the rear cabin temperature, which is used to control the air conditioning system. The resistance of the cooler (No. 2 room temp. sensor) thermistor changes in accordance with the rear cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the cooler (No. 2 room temp. sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (No. 2 room temp. sensor) thermistor.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1419/19 Rear Room Temperature Sensor Circuit Open or short in rear room temperature sensor circuit
·

Cooler (No. 2 room temp. sensor) thermistor

·

Harness or connector between cooler (No. 2 room temp. sensor) thermistor and air conditioning amplifier assembly

·

Air conditioning amplifier assembly


Memorized
(4 sec. or more)*1

*1: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


WIRING DIAGRAM

E236721E60
2.146,0.448 2.531,0.844 0.385,0.396 10 false 1 2.146,1.396 2.646,1.729 0.5,0.333 10 false 2 5.115,0.448 5.552,0.75 0.438,0.302 10 false 20 5.177,1.396 5.396,1.656 0.219,0.26 10 false 8 5.396,0.542 6.146,0.958 0.75,0.417 10 false TR 5.396,1.49 6.146,1.833 0.75,0.344 10 false RGND 0.958,1.813 1.281,1.99 0.323,0.177 10 false L17 0.948,1.979 2.594,2.375 1.646,0.396 10 false Cooler (No. 2 Room Temp. Sensor) Thermistor 5.052,1.885 5.5,2.156 0.448,0.271 10 false F81 5.052,2.052 6.635,2.521 1.583,0.469 10 false Air Conditioning Amplifier Assembly

PROCEDURE

1.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temp Sensor (Rear) Cooler (No. 2 room temp. sensor) thermistor Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual rear cabin temperature displayed -
Body Electrical > Air Conditioner > Data List
Tester Display
Room Temp Sensor (Rear)
50003 121 54
OK:

The display is as specified in the normal condition column.



Result:
Result Proceed to
NG A
OK (When troubleshooting according to Problem Symptoms Table) B
OK (When troubleshooting according to the DTC) C



A

2.INSPECT COOLER (NO. 2 ROOM TEMP. SENSOR) THERMISTOR

B

C

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

2.INSPECT COOLER (NO. 2 ROOM TEMP. SENSOR) THERMISTOR
a.
E285449C01
1.729,3.188 1.969,2.896 false 0.208,0.188 0.521,0.344 0.313,0.156 10 false *a 0.25,2.969 0.563,3.125 0.313,0.156 10 false *b 1.948,4.385 2.26,4.542 0.313,0.156 10 false *c 1.99,2.74 2.302,2.896 0.313,0.156 10 false *d 1.125,4.167 1.417,4.385 0.292,0.219 10 false (68) 0.625,4.167 0.917,4.385 0.292,0.219 10 false (50) 1.625,4.156 1.917,4.375 0.292,0.219 10 false (86) 2.115,4.167 2.49,4.417 0.375,0.25 10 false (104) 2.625,4.167 3,4.417 0.375,0.25 10 false (122) 3.094,4.167 3.427,4.417 0.333,0.25 10 false (140)
*a Component without harness connected
(Cooler (No. 2 Room Temp. Sensor) Thermistor)
*b Resistance (kΩ)
*c Temperature (°C (°F))
*d Allowable Range


Remove the cooler (No. 2 room temp. sensor) thermistor.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR(for Rear)>REMOVAL


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:

When measuring, the sensor temperature must be the same as the ambient temperature.


HINT:

As the temperature increases, the resistance decreases (see the graph).



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (COOLER (NO. 2 ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPLACE COOLER (NO. 2 ROOM TEMP. SENSOR) THERMISTOR

3.CHECK HARNESS AND CONNECTOR (COOLER (NO. 2 ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the F81 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F81-20 (TR) - L17-1 Always Below 1 Ω
F81-8 (RGND) - L17-2 Always Below 1 Ω
F81-20 (TR) - Body ground Always 10 kΩ or higher
F81-8 (RGND) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR