89341K
1.INSPECT NO. 1 ULTRASONIC SENSOR
| *a | Component without harness connected
(No. 1 Ultrasonic Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (S) - 1 (E) | Always | 20 to 40 kΩ |
If the result is not as specified, replace the No. 1 ultrasonic sensor.