Home › Engine / Hybrid System › 2GR-FKS (COOLING) › COOLING FAN MOTOR › from 2016.11
RM3160E _51 Engine / Hybrid System _060161 2GR-FKS COOLING _0297918 COOLING FAN MOTOR G

2GR-FKS COOLING  COOLING FAN MOTOR  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 16363G 1.INSPECT COOLING FAN MOTOR LH

a.

Disconnect the cooling fan motor LH connector.


b.
A255683C12
1.979,1.375 2.542,1.375 false 0.875,1.365 1.448,1.365 false 0.073,0.031 0.281,0.25 0.208,0.219 10 false *a 2.615,1.271 2.854,1.49 0.24,0.219 10 false (+) 0.646,1.26 0.885,1.479 0.24,0.219 10 false (-)
*a Component without harness connected
(Cooling Fan Motor LH)


Check that the cooling fan motor LH operates smoothly when the battery is connected to the cooling fan motor LH connector.


c.

Measure the current while the cooling fan motor LH is operating.

Standard Current:
Condition Specified Condition
Battery voltage applied at 20°C (68°F) 11.5 to 17.5 A


If the result is not as specified, replace the cooling fan motor LH.


d.

Connect the cooling fan motor LH connector.


Hide 16363F 2.INSPECT COOLING FAN MOTOR RH

a.

Disconnect the cooling fan motor connector RH.


b.
A255684C16
1.969,1.438 2.531,1.438 false 0.885,1.438 1.448,1.438 false 0.083,0.063 0.292,0.281 0.208,0.219 10 false *a 2.594,1.354 2.833,1.573 0.24,0.219 10 false (+) 0.698,1.365 0.938,1.583 0.24,0.219 10 false (-)
*a Component without harness connected
(Cooling Fan Motor)


Check that the cooling fan motor RH operates smoothly when the battery is connected to the cooling fan motor RH connector.


c.

Measure the current while the cooling fan motor RH is operating.

Standard Current:
Condition Specified Condition
Battery voltage applied at 20°C (68°F) 11.5 to 17.5 A


If the result is not as specified, replace the cooling fan motor RH.


d.

Connect the cooling fan motor RH connector.