Home › General › SPECIFICATIONS › 1AR-FE COOLING › from 2016.11
RM3160E _V1 General _019682 SPECIFICATIONS _0095367 1AR-FE COOLING F

SPECIFICATIONS  1AR-FE COOLING  SERVICE DATA  


THERMOSTAT
Condition Specified Condition
Standard valve opening temperature 80 to 84°C (176 to 183°F)
Standard valve lift 10 mm (0.394 in.) or more at 95°C (203°F)

COOLING FAN MOTOR
Item Condition Specified Condition
Cooling fan motor Battery voltage applied at 20°C (68°F) 13.6 to 19.6 A
No. 2 cooling fan motor Battery voltage applied at 20°C (68°F) 13.6 to 19.6 A

COOLING FAN RELAY
Tester Connection Condition Specified Condition
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Battery voltage applied between terminals 1 and 2 Below 1 Ω

RADIATOR
Item Condition Specified Condition
Radiator cap Standard value (for brand-new cap) 93 to 123 kPa (0.9 to 1.3 kgf/cm2, 13.5 to 18.0 psi)
Minimum standard value (for used cap) 79 kPa (0.8 kgf/cm2, 11.5 psi)

COOLANT
Capacity Classification
9.8 liters (10.4 US qts, 8.6 Imp. qts) Use only "TOYOTA Super Long Life Coolant", or similar high quality ethylene glycol based non-silicate, non-amine, non-nitrite, and non-borate coolant with long-life hybrid organic acid technology (coolant with long-life hybrid organic acid technology is a combination of low phosphates and organic acids).