Home › Power Source / Network › 2GR-FKS BATTERY / CHARGING › CHARGING SYSTEM › from 2016.11
RM3160E _57 Power Source / Network _060166 2GR-FKS BATTERY / CHARGING _0299738 CHARGING SYSTEM L

2GR-FKS BATTERY / CHARGING  CHARGING SYSTEM  PRECAUTION  


INITIALIZATION


NOTICE:

When the cable is disconnected from the negative (-) battery terminal, initialize the following system(s) after the cable is reconnected.

System Name See Procedure
Lane Departure Alert System (w/ Steering Control) (Click here)
Parking Assist Monitor System
Panoramic View Monitor System
Power Door Lock Control System
Pre-collision System
Air Conditioning System
(for Automatic Air Conditioning System)
Air Conditioning System
(for Manual Air Conditioning System)
Power Back Door System



IGNITION SWITCH EXPRESSIONS


HINT:

The type of ignition switch used on this model differs depending on the specifications of the vehicle. The expressions listed in the table below are used in this section.

Expression Ignition Switch (Position) Engine Switch (Condition)
Ignition Switch off LOCK Off (Lock)
Ignition Switch ACC ACC On (ACC)
Ignition Switch ON ON On (IG)
Engine Start START On (Start)



CHARGING SYSTEM PRECAUTION


NOTICE:
·

Check that the battery cables are connected to the correct terminals.

·

Disconnect the battery cables when the battery is given a quick charge.

·

Do not perform tests with a high voltage insulation resistance tester.

·

Never disconnect the battery cables while the engine is running.

·

Check that the charging cable nuts are tightened on terminal B of the generator assembly and on the No. 1 engine room relay block and No. 1 junction block assembly.