Home › Engine / Hybrid System › 2GR-FKS (INTAKE / EXHAUST) › VACUUM SWITCHING VALVE(for ACIS) › from 2016.11
RM3160E _51 Engine / Hybrid System _060160 2GR-FKS INTAKE / EXHAUST _0299814 VACUUM SWITCHING VALVE(for ACIS) G

2GR-FKS INTAKE / EXHAUST  VACUUM SWITCHING VALVE(for ACIS)  INSPECTION  


PROCEDURE

Hide 25860 1.INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)

a.
A370423C01
1.052,4.521 1.198,4.521 1.198,4.521 1.479,4.031 true 0.865,4.427 1.063,4.646 0.198,0.219 10 false *a 0.083,1.615 0.292,1.823 0.208,0.208 10 false *b
*a Valve Body
*b Component without harness connected
(No. 1 vacuum switching valve assembly (for ACIS))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - No. 1 vacuum switching valve assembly (for ACIS) body ground Always 10 kΩ or higher
2 - No. 1 vacuum switching valve assembly (for ACIS) body ground


If the result is not as specified, replace the No. 1 vacuum switching valve assembly (for ACIS).


b.

Check the No. 1 vacuum switching valve assembly (for ACIS) operation.

i.
A371407C01
0.802,4.01 0.979,4.01 0.979,4.01 1.115,3.469 true 2.646,3.927 2.417,3.927 2.417,3.927 2.24,3.229 true 2.708,3.844 3.021,4.135 0.313,0.292 10 false *a 0.594,3.906 0.99,4.208 0.396,0.302 10 false *b 3.063,2.521 3.365,2.76 0.302,0.24 10 false *c
*a Filter
*b Port (E)
*c Air


When vacuum is applied to the port (E), check that air is sucked into the filter.

If the result is not as specified, replace the No. 1 vacuum switching valve assembly (for ACIS).


ii.
A370424C01
0.208,3.917 0.208,3.75 0.208,3.75 0.396,3.531 true 0.938,4.24 0.938,3.479 0.938,3.479 0.656,3.375 true 0.875,4.271 1.24,4.49 0.365,0.219 10 false *a 0.146,3.969 0.396,4.198 0.25,0.229 10 false *b 0.75,2.115 1.021,2.344 0.271,0.229 10 false *c
*a Port (E)
*b Port (F)
*c Air


Apply battery voltage across the terminals. When vacuum is applied to the port (F), check that air is sucked into the port (E).

If the result is not as specified, replace the No. 1 vacuum switching valve assembly (for ACIS).