RM3160E
_V1
General
_019682
SPECIFICATIONS
_0294996
2GR-FKS INTAKE / EXHAUST
F
SPECIFICATIONS 2GR-FKS INTAKE / EXHAUST SERVICE DATA
VACUUM SWITCHING VALVE (for ACIS)
| Tester Connection
|
Condition
|
Specified Condition
|
| 1 - 2
|
20°C (68°F)
|
33 to 39 Ω
|
| 1 - No. 1 vacuum switching valve assembly (for ACIS) body ground
|
Always
|
10 kΩ or higher
|
| 2 - No. 1 vacuum switching valve assembly (for ACIS) body ground
|
EXHAUST PIPE
| Compression spring
|
Standard length
|
43.0 mm (1.69 in.)
|
| Minimum free length
|
41.5 mm (1.63 in.)
|