Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) › from 2016.11
RM3160E _58 Vehicle Interior _019714 HEATING / AIR CONDITIONING _0109951 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1412/12  Ambient Temperature Sensor Circuit  


DESCRIPTION

The thermistor assembly is installed in front of the cooler condenser assembly to detect the ambient temperature, which is used to control the air conditioning system. This sensor is connected to the air conditioning amplifier assembly and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the thermistor assembly changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the thermistor assembly and reads voltage changes due to changes in the resistance of the thermistor assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1412/12 Ambient Temperature Sensor Circuit Open or short in ambient temperature sensor circuit
·

Thermistor assembly

·

Harness or connector between thermistor assembly and air conditioning amplifier assembly

·

Air conditioning amplifier assembly


Memorized
(4 sec. or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


HINT:

If the ambient temperature is approximately -52.9°C (-63.22°F) or lower, DTC B1412/12 may be output even though the system is normal.


WIRING DIAGRAM

E202728E44
0.969,1.823 1.281,2.021 0.313,0.198 10 false A80 0.958,1.979 2.49,2.229 1.531,0.25 10 false Thermistor Assembly 2.25,1.125 2.406,1.323 0.156,0.198 10 false - 2.24,0.667 2.396,0.865 0.156,0.198 10 false + 2.448,0.677 2.604,0.875 0.156,0.198 10 false 2 2.438,1.135 2.594,1.333 0.156,0.198 10 false 1 5.021,0.698 5.333,0.896 0.313,0.198 10 false 5 4.958,1.167 5.271,1.365 0.313,0.198 10 false 13 5.24,0.813 5.698,1.01 0.458,0.198 10 false TAM 5.24,1.271 5.698,1.469 0.458,0.198 10 false SG-2 4.729,1.792 5.188,1.99 0.458,0.198 10 false F80 4.708,1.938 7.073,2.188 2.365,0.25 10 false Air Conditioning Amplifier Assembly

PROCEDURE

1.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Data List.


e.

Check the value(s) by referring to the table below.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ambient Temp Sensor Thermistor assembly Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature displayed -
Body Electrical > Air Conditioner > Data List
Tester Display
Ambient Temp Sensor
50003 121 2
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.INSPECT THERMISTOR ASSEMBLY
2.INSPECT THERMISTOR ASSEMBLY
E356182C01
0.448,0.771 0.323,1.198 false 2.375,1.083 2.552,0.719 false 2.885,1.083 2.698,0.719 false 1.531,3.083 2.042,2.76 false 0.26,1.24 0.573,1.438 0.313,0.198 10 false *b 0.177,0.135 0.49,0.333 0.313,0.198 10 false *a 2.885,1.073 3.042,1.271 0.156,0.198 10 false - 2.323,1.083 2.479,1.281 0.156,0.198 10 false + 0.208,2.823 0.521,3.021 0.313,0.198 10 false *c 1.927,4.365 2.24,4.563 0.313,0.198 10 false *d 0.573,4.177 1.188,4.375 0.615,0.198 10 false (50) 1.073,4.177 1.438,4.385 0.365,0.208 10 false (68) 1.583,4.177 1.948,4.385 0.365,0.208 10 false (86) 2.073,4.177 2.438,4.385 0.365,0.208 10 false (104) 2.594,4.177 2.958,4.385 0.365,0.208 10 false (122) 3.083,4.177 3.427,4.406 0.344,0.229 10 false (140) 2.083,2.625 2.396,2.823 0.313,0.198 10 false *e
*a Component without harness connected
(Thermistor Assembly)
*b Sensing Portion
*c Resistance (kΩ)
*d Temperature (°C (°F))
*e Allowable Range



b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (-) - 2 (+) 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Hold the sensor only by its connector. Touching the sensing portion may change the resistance value.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

3.CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY)
a.

Disconnect the F80 air conditioning amplifier assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A80-2 (+) - F80-5 (TAM) Always Below 1 Ω
A80-1 (-) - F80-13 (SG-2) Always Below 1 Ω
A80-2 (+) or F80-5 (TAM) - Body ground Always 10 kΩ or higher
A80-1 (-) or F80-13 (SG-2) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR