85910E
1.INSPECT INJECTOR RELAY (D INJ)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the injector relay (D INJ).
28380
2.INSPECT FUEL PUMP RELAY ASSEMBLY (FUEL PMP)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied between terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the fuel pump relay (FUEL PMP).