UA80E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSAXLE SYSTEM  P071015  Transmission Fluid Temperature Sensor "A" Circuit Short to Battery or Open  


DESCRIPTION

The ATF temperature sensor converts the automatic transaxle fluid (ATF) temperature into a resistance value for use by the ECM.

The ECM applies voltage to the temperature sensor through terminal THO1 of the ECM.

The sensor resistance changes with the ATF temperature. As the temperature rises, the sensor resistance decreases.

One terminal of the sensor is grounded so that the sensor resistance and voltage decrease as the temperature rises.

The ECM calculates the ATF temperature based on the voltage signal.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P071015 Transmission Fluid Temperature Sensor "A" Circuit Short to Battery or Open 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
DTC Detection Condition 1
1.

900 seconds or more have elapsed since the engine was started when the engine coolant temperature and intake air temperature were -29.375°C (-20.875°F) or less.

2.

ATF temperature sensor voltage is more than 4.915 V

3.

0.5 seconds

4.

1-trip detection logic


DTC Detection Condition 2
1.

10 seconds or more have elapsed since the engine was started when the engine coolant temperature and intake air temperature were more than -29.375°C (-20.875°F).

2.

ATF temperature sensor voltage is more than 4.915 V

3.

0.5 seconds

4.

1-trip detection logic


·

Open or short to +B in ATF temperature sensor circuit

·

Transmission wire (ATF temperature sensor)

·

ECM


Comes on DTC stored SAE Code:
P0713

MONITOR DESCRIPTION

This DTC indicates an open or short to +B in the ATF temperature sensor circuit. The ATF temperature sensor converts the ATF temperature into an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature, and can detect an open or short in the ATF temperature sensor circuit. If the resistance value of the ATF temperature sensor is higher than 156 kΩ*, the ECM interprets this as a malfunction of the ATF temperature sensor or in the wire harness, illuminates the MIL and stores this DTC.

*: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

HINT:

The ATF temperature can be checked in the Data List.


CAUTION / NOTICE / HINT

NOTICE:

Perform registration and/or initialization when parts related to the automatic transaxle are replaced.

Click hereDrivetrain>UA80E (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSAXLE SYSTEM>PRECAUTION


HINT:

After performing repair, clear the DTCs and perform the following procedure to check that DTCs are not output.

1.

Start the engine and wait for 15 minutes or more.



DATA LIST


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / Transmission / Data List / A/T Oil Temperature No.1.


g.

Read the Data List according to the display on the GTS.

Powertrain > Transmission > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
A/T Oil Temperature No.1 ATF temperature sensor value Min.: -40°C (-40°F)
Max.: 150°C (302°F)
·

Approximately 80°C (176°F): After stall speed test

·

Equal to ambient temperature: When engine is cold


If value is -40°C (-40°F) or 150°C (302°F), ATF temperature sensor circuit is open or shorted
Powertrain > Transmission > Data List
Tester Display
A/T Oil Temperature No.1
50003 373 180
HINT:
·

If DTC P071011 is output and the GTS indicates 150°C (302°F) or higher, there is a short in the circuit.

·

If DTC P071015 is output and the GTS indicates -40°C (-40°F), the circuit is open.

Check the temperature displayed on the GTS in order to check if a malfunction exists.

Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or higher Short circuit

·

If a circuit related to the ATF temperature sensor becomes open, P071015 will be stored in approximately 0.5 seconds. If DTC P071015 is stored, DTC P071000 cannot be detected. It is not necessary to inspect the circuit when P071000 is output.





PROCEDURE

1.INSPECT TRANSMISSION WIRE (ATF TEMPERATURE SENSOR)
a.
C361126C01
2.542,0.875 2.833,0.333 true 2.281,0.854 2,0.333 true 2.896,0.25 3.354,0.448 0.458,0.198 10 false OT+ 1.708,0.25 2.167,0.448 0.458,0.198 10 false OT- 0.094,0.094 0.406,0.292 0.313,0.198 10 false *a
*a Component without harness connected
(Transmission Wire)


Disconnect the C85 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (OT+) - 2 (OT-) Always 79 Ω to 156 kΩ
1 (OT+) or 2 (OT-) - Other terminals Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at any of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.

ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.

Disconnect the C1 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C1-86 (THO1) - C1-133 (ETHW) Always 79 Ω to 156 kΩ
C1-86 (THO1) or C1-133 (ETHW) - Other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.REPLACE ECM

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.REPLACE ECM

Result:
Proceed to
NEXT



NEXT