With the front fender apron assembly removed.
REMOVAL
| Symbol Meaning | |
|---|---|
|
Remove Weld Points |
Do not butt weld or heat repair because the heat decreases the strength of areas where ultra high strength steel is used. (See the introduction)
Remove the A.
Remove the A.
Remove the front side member assembly.
| *1 | FRONT SIDE MEMBER ASSEMBLY | - | - |
INSTALLATION
| Symbol Meaning | |
|---|---|
|
Remove Weld Points |
|
Plug Weld |
Temporarily install the new parts and measure each part of the new parts in accordance with the body dimension diagram. (See the body dimensions)
Make sure to attach correctly in accordance with the body dimension diagram as this part affects the front wheel alignment.
Weld the front side member assembly to the vehicle side.
| *1 | FRONT SIDE MEMBER ASSEMBLY | - | - |
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 2 panels together including 980 MPa or 780 MPa ultra high strength steel.
| *a: Plug weld | Plug diameter | 10 mm (0.39 in.) |
| Wire type | AWS A5.18 ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar 80% + CO2 20%) as the shield gas when plug welding.Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
| *A | LH | *B | RH |
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 2 panels together including 780 MPa ultra high strength steel.
| *a: Plug weld | Plug diameter | 10 mm (0.39 in.) |
| Wire type | AWS A5.18 ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar 80% + CO2 20%) as the shield gas when plug welding.Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
Remove A from the new parts.
| *1 | FRONT SIDE MEMBER REINFORCEMENT SUB-ASSEMBLY | - | - |
Weld the A to the vehicle side.
| *a | Ultra High Strength Steel Welding Point | - | - |
When welding 2 panels together including 780 MPa ultra high strength steel.
| *a: Plug weld | Plug diameter | 10 mm (0.39 in.) |
| Wire type | AWS A5.18 ER70S-3 | |
| Shield gas | Metal active gas |
Be sure to use Metal active gas (Ar 80% + CO2 20%) as the shield gas when plug welding.Sufficient weld strength cannot be assured when using 100% CO2 shield gas.
Weld the A to the vehicle side.
After welding, apply body sealer and undercoating to the corresponding parts. (See the painting/coating)
After applying the top coat, apply anti-rust agent to the internal panel portion of the closed section structural weld points.