REMOVAL
| Symbol Meaning | |
|---|---|
|
Remove Weld Points |
|
Remove Weld Points |
INSTALLATION
| Symbol Meaning | |
|---|---|
|
Spot Weld |
|
Plug Weld |
|
Plug Weld |
|
Body Sealer |
Inspect the fitting of the related parts around the new parts before welding. This affects the appearance of the finish.
Temporarily install the new parts and measure each part of the new parts in accordance with the body dimension diagram. (See the body dimensions)
Before temporarily installing the new parts, apply body sealer to the roof panel reinforcement No.1, roof panel reinforcement No.3, roof panel reinforcement No.4, roof panel reinforcement No.5 and roof panel reinforcement No.6.
Apply enough body sealer to the panels.
| *1 | ROOF PANEL REINFORCEMENT NO.1 | *2 | ROOF PANEL REINFORCEMENT NO.3 |
| *3 | ROOF PANEL REINFORCEMENT NO.4 | *4 | ROOF PANEL REINFORCEMENT NO.5 |
| *5 | ROOF PANEL REINFORCEMENT NO.6 | - | - |
Before temporarily installing the new parts, weld the roof panel, roof panel reinforcement No.1, roof panel reinforcement No.3, roof panel reinforcement No.4, roof panel reinforcement No.5 and roof panel reinforcement No.6 with the standard number of welding points.
| *1 | ROOF PANEL | *2 | ROOF PANEL REINFORCEMENT NO.1 |
| *3 | ROOF PANEL REINFORCEMENT NO.3 | *4 | ROOF PANEL REINFORCEMENT NO.4 |
| *5 | ROOF PANEL REINFORCEMENT NO.5 | *6 | ROOF PANEL REINFORCEMENT NO.6 |
Before temporarily installing the new parts, apply body sealer to the windshield header panel sub-assembly, roof panel reinforcement sub-assembly and back door opening frame sub-assembly.
Apply enough body sealer to the panels.
| *1 | WINDSHIELD HEADER PANEL SUB-ASSEMBLY | *2 | ROOF PANEL REINFORCEMENT SUB-ASSEMBLY |
| *3 | BACK DOOR OPENING FRAME SUB-ASSEMBLY | - | - |
After welding, apply the foamed sealing material to the corresponding parts. (See the painting/coating)
After welding, apply body sealer to the corresponding parts. (See the painting/coating)
After applying the top coat, apply anti-rust agent to the internal panel portion of the closed section structural weld points.
Measure the dimensions before installing the roof panel.
| Area | Measurement | Area | Measurement |
|---|---|---|---|
| A | 800 mm (31.50 in.) | B | 715 mm (28.15 in.) |
| C | 900 mm (35.43 in.) | D | 1058 mm (41.65 in.) |
| E | 1276 mm (50.24 in.) | F | 1551 mm (61.06 in.) |
| G | 2111 mm (83.11 in.) | H | 2444 mm (96.22 in.) |
| I | 878 mm (34.57 in.) | J | 1036 mm (40.79 in.) |
| K | 1279 mm (50.35 in.) | L | 1531 mm (60.28 in.) |
| M | 2108 mm (82.99 in.) | N | 2433 mm (95.79 in.) |