Home › Engine / Hybrid System › A25A-FXS, A25B-FXS (COOLING) › COOLANT FLOW › 2020.02–2021.10
NM37A0E _51 Engine / Hybrid System _086674 A25A-FXS COOLING _0415627 COOLANT FLOW CO CONTROL F

A25A-FXS COOLING  COOLANT FLOW  CONTROL  VARIABLE COOLING CONTROL  


FUNCTION OF MAIN COMPONENTS


Component Function
Flow Shutting Valve (Water Valve) Selects a coolant passage based on signals from the ECM.
Engine Water Pump Assembly (Water Inlet Housing) Optimizes coolant circulation based on signals from the ECM.
Water Inlet with Thermostat Sub-assembly Thermostat Heater Assists opening the thermostat heater valve based on signals from the ECM.
Engine Coolant Temperature Sensor Detects the engine coolant temperature.


FUNCTION


a.

By using the variable cooling system that consists of the thermostat with heater, engine water pump assembly (water inlet housing) and flow shutting valve (water valve), engine warm-up capability has been enhanced, friction has been reduced and low fuel consumption has been achieved.

W136615E04
5.302,2.135 5.177,2.135 5.177,2.135 5.01,2.76 true 5.115,3.74 4.99,3.74 4.99,3.74 4.802,4.635 true 0.083,0.563 1.354,1.01 1.271,0.448 10 false Thermostat Opening Amount 1.229,1.073 1.719,1.292 0.49,0.219 10 false Open 1.125,1.5 1.719,1.74 0.594,0.24 10 false Closed 0.083,2.125 1,2.365 0.917,0.24 10 false Flow Rate 2.302,2.698 2.542,2.896 0.24,0.198 10 false *a 5.542,2.688 5.792,2.917 0.25,0.229 10 false *b 0.083,3.417 1.385,3.635 1.302,0.219 10 false Cooling Fan Speed 3.438,5.313 5.427,5.521 1.99,0.208 10 false Engine Coolant Temperature 0.875,4.552 1.667,4.781 0.792,0.229 10 false Low Speed 4.479,5 4.833,5.198 0.354,0.198 10 false 92 6.448,5 7.01,5.219 0.563,0.219 10 false (°C) 5.365,2.052 6.115,2.26 0.75,0.208 10 false High Load 0.354,2.854 1.75,3.104 1.396,0.25 10 false Standard Flow Rate 3.073,5 3.427,5.198 0.354,0.198 10 false 82 0.875,4.208 1.635,4.406 0.76,0.198 10 false Mid Speed 0.875,3.885 1.667,4.135 0.792,0.25 10 false High Speed 5.167,3.635 5.479,3.854 0.313,0.219 10 false *c 3.104,0.156 4.875,0.365 1.771,0.208 10 false Standard Flow Rate Control 6.021,4.01 6.771,4.219 0.75,0.208 10 false High Load 4.885,4.656 5.531,4.865 0.646,0.208 10 false Low Load

Text in Illustration
*a The engine coolant flow rate is less than standard when the thermostat is closed. When the air conditioning system is operating, the flow rate required by the air conditioning system is used if it is higher than the standard flow rate. *b After the thermostat opens, the engine coolant flow rate remains the same until the engine is subjected to high load, at which time the flow rate is increased. The engine coolant flow rate is not decreased below the standard flow rate. When the air conditioning system is operating, the flow rate required by the air conditioning system is used if it is higher than the standard flow rate.
*c The temperature at which the cooling fan starts operating changes depending on the engine conditions. - -

i.

When the engine is warming up

·

The engine coolant flow rate is controlled at less than the standard flow rate based on the engine temperature.


W136612C01
2.833,1 3.146,1.156 0.313,0.156 10 false *1 4.5,0.635 4.813,0.792 0.313,0.156 10 false *2 4.292,1.146 4.604,1.302 0.313,0.156 10 false *3 2.521,1.708 2.833,1.865 0.313,0.156 10 false *4 3.156,1.76 3.469,1.917 0.313,0.156 10 false *5 3.365,2.271 3.677,2.427 0.313,0.156 10 false *6 3.604,1.135 3.917,1.292 0.313,0.156 10 false *a
*1 Engine *2 Flow Shutting Valve (Water Valve) (Open)
*3 Heater Radiator Unit Sub-assembly *4 Engine Water Pump Assembly (Water Inlet Housing)
*5 Water Inlet with Thermostat Sub-assembly
·

Thermostat with Heater


*6 Radiator Assembly
*a EGR Cooler Assembly, etc. - -



ii.

When the engine is warm (after the thermostat opens)

·

During high load, the engine coolant flow rate is controlled at more than the standard flow rate depending on the coolant temperature in order to prevent knocking.


W136613C01
2.833,0.969 3.146,1.125 0.313,0.156 10 false *1 4.458,0.625 4.771,0.781 0.313,0.156 10 false *2 4.292,1.156 4.604,1.313 0.313,0.156 10 false *3 2.542,1.719 2.854,1.875 0.313,0.156 10 false *4 3.156,1.781 3.469,1.938 0.313,0.156 10 false *5 3.396,2.281 3.708,2.438 0.313,0.156 10 false *6 3.604,1.135 3.917,1.292 0.313,0.156 10 false *a
*1 Engine *2 Flow Shutting Valve (Water Valve) (Open)
*3 Heater Radiator Unit Sub-assembly *4 Engine Water Pump Assembly (Water Inlet Housing)
*5 Water Inlet with Thermostat Sub-assembly
·

Thermostat with Heater


*6 Radiator Assembly
*a EGR Cooler Assembly, etc. - -



iii.

When the air conditioning system is operating.

·

The flow of engine coolant to the heater radiator unit sub-assembly is stopped in order to improve the cooling efficiency of the air conditioning system.


W136614C01
2.844,1.01 3.156,1.167 0.313,0.156 10 false *1 4.448,0.625 4.76,0.781 0.313,0.156 10 false *2 4.292,1.156 4.604,1.313 0.313,0.156 10 false *3 2.552,1.719 2.865,1.875 0.313,0.156 10 false *4 3.135,1.781 3.448,1.938 0.313,0.156 10 false *5 3.365,2.271 3.677,2.427 0.313,0.156 10 false *6 3.615,1.146 3.927,1.302 0.313,0.156 10 false *a
*1 Engine *2 Flow Shutting Valve (Water Valve) (Closed)
*3 Heater Radiator Unit Sub-assembly *4 Engine Water Pump Assembly (Water Inlet Housing)
*5 Water Inlet with Thermostat Sub-assembly
·

Thermostat with Heater


*6 Radiator Assembly
*a EGR Cooler Assembly, etc. - -