Home › Engine / Hybrid System › A25A-FXS, A25B-FXS (COOLING) › COOLANT FLOW
NM37A0E _51 Engine / Hybrid System _086674 A25A-FXS, A25B-FXS COOLING _0415627 COOLANT FLOW DE DETAILS F

A25A-FXS, A25B-FXS COOLING  COOLANT FLOW  DETAILS  FLOW SHUTTING VALVE  


CONSTRUCTION


a.

When the flow shutting valve (water valve) is closed and electric current is applied, a magnetic field is generated between the yoke, valve and core, which keeps the valve closed.


b.

When there is no current applied to the flow shutting valve (water valve) and the water pump operates, the valve opens due to engine coolant pressure.


c.

The opened valve remains open until the engine coolant flow stops.

W136155C01
2.583,0.333 3.417,0.333 true 2.583,0.771 2.917,0.771 2.917,0.771 3.417,1.188 true 2.583,1.552 3.417,1.552 true 4.333,1.333 4.833,0.75 4.833,0.75 5.083,0.75 true 4.469,1.333 5.052,1.333 true 3.792,1.604 4.625,2.188 4.625,2.188 4.958,2.188 true 2.406,0.229 2.594,0.427 0.188,0.198 10 false *1 2.396,0.677 2.573,0.875 0.177,0.198 10 false *2 2.406,1.448 2.583,1.635 0.177,0.188 10 false *3 5.104,0.646 5.302,0.844 0.198,0.198 10 false *4 5.083,1.24 5.271,1.438 0.188,0.198 10 false *5 4.979,2.083 5.156,2.281 0.177,0.198 10 false *6
*1 Housing *2 Spring
*3 Valve *4 Core
*5 Coil *6 Yoke