Home › Engine / Hybrid System › 2GR-FKS (IDLING STOP CONTROL) › STOP AND START › from 2020.11
NM37A0E _51 Engine / Hybrid System _096486 2GR-FKS IDLING STOP CONTROL _0453093 STOP AND START CO CONTROL F

2GR-FKS IDLING STOP CONTROL  STOP AND START  CONTROL  OIL PUMP WITH SOLENOID CONTROL  


SYSTEM CONTROL


a.

During an idling stop, the engine stop and start ECU operates the oil pump with solenoid assembly. As a result, ATF pressure is ensured during idling stops, achieving a natural response and smooth driveability when the vehicle is started off from an engine stopped condition.

Y177237E05
2,2 2.333,2 2.333,2 2.333,1.417 true 5.708,0.885 6.604,2.115 0.896,1.229 10 false Oil Pump with Solenoid Assembly 4.458,1.49 5.094,2.104 0.635,0.615 10 false Operation Voltage 2.917,0.531 3.969,1.177 1.052,0.646 10 false Engine Stop and Start ECU 3.021,1.542 3.917,2.135 0.896,0.594 10 false Backup Boost Converter 0.344,1.896 1.969,2.104 1.625,0.208 10 false CAN Communication Line 0.781,1.26 1.26,1.51 0.479,0.25 10 false ECM


b.

The engine stop and start ECU sends a pump operation signal to the oil pump with solenoid assembly when the following conditions are met.


c.

The engine restarts, and the engine stop and start ECU stops the oil pump with solenoid assembly when it determines that the engine is in operation. Also, even during an idling stop, operation is stopped when the shift range is not in D.

Oil Pump with Solenoid Assembly Operation
Shift Position P R N D S

○: Operating

-: Idling stop is disabled

Brake On (Applied) - - - ○ -
Brake Off (not Applied) - - - - -

Oil Pump with Solenoid Assembly Operation Condition
Item Condition Remarks
ATF Temperature 25°C to 110°C (77°F to 230°F) Detected from the ATF temperature sensor in the AT