CONSTRUCTION
Front Air Conditioning Unit Assembly
An air conditioning unit that is compatible with left and right independent temperature control is used.
An inside-and-outside dual air layer type air conditioning unit is used. This type of air conditioning unit introduces outside air to the upper side and circulates inside air to the lower side, thus achieving anti-fogging performance and ventilation loss reduction.
A Beneficial Refrigerant Stream (BRS) type evaporator is used.
A Straight Flow Aluminum-II (SFA-II) heater core that is compact and offers advanced performance is used.
A compact wide-angle high flow defroster that gives the defroster nozzle assembly inner wall a radial shape is used to ensure superior defroster performance.
Rear Air Conditioning Unit Assembly
A Revolutionary Super-slim (RS) type evaporator is used.
A Straight Flow Aluminum-II (SFA-II) heater core that is compact and offers advanced performance is used.
Air Conditioning Unit Layout Parts Location
| *1 | Front Air Conditioning Unit Assembly | *2 | Rear Air Conditioning Unit Assembly |
| *1 | Front Air Conditioning Unit Assembly | *2 | Rear Air Conditioning Unit Assembly |
Duct Layout Parts Location
from Front Air Conditioning Unit Assembly
| *1 | Front Defroster Duct | *2 | Driver Side Defroster Duct |
| *3 | Driver Side Register Duct | *4 | Driver Side Footwell Register Duct |
| *5 | Driver Side Rear Footwell Register Duct | *6 | Front Passenger Side Defroster Duct |
| *7 | Front Passenger Side Register Duct | *8 | Center Register Duct |
| *9 | Front Passenger Side Footwell Register Duct | *10 | Passenger Side Rear Footwell Register Duct |
| *1 | Front Defroster Duct | *2 | Driver Side Defroster Duct |
| *3 | Driver Side Register Duct | *4 | Driver Side Footwell Register Duct |
| *5 | Driver Side Rear Footwell Register Duct | *6 | Front Passenger Side Defroster Duct |
| *7 | Front Passenger Side Register Duct | *8 | Center Register Duct |
| *9 | Front Passenger Side Footwell Register Duct | *10 | Passenger Side Rear Footwell Register Duct |
from Rear Air Conditioning Unit Assembly
| *1 | Rear Passenger Register Duct | *2 | Rear Passenger Footwell Register Duct |
OPERATION
Mode Position and Damper Operation
| *A | Gasoline Models | *B | Models with PTC Heater |
| *1 | Driver Side Air Mix Control Damper | *2 | Front Passenger Side Air Mix Control Damper |
| *3 | Driver Side Side Defroster | *4 | Front Defroster |
| *5 | Front Passenger Side Side Defroster | *6 | Air Inlet Control Damper (Lower Side) |
| *7 | Air Inlet Control Damper (Upper Side) | *8 | Clean Air Filter |
| *9 | Blower with Fan Motor Sub-assembly | *10 | No. 1 Cooler Evaporator Sub-assembly |
| *11 | Air Mix Control Damper | *12 | Heater Radiator Unit Sub-assembly |
| *13 | PTC Heater (Quick Heater Assembly) | *14 | Mode Switching Damper |
| *15 | Driver Side Footwell Register | *16 | Front Passenger Side Footwell Register |
| *17 | Driver Side Side Register | *18 | Center Register |
| *19 | Front Passenger Side Side Register | *20 | Driver Side Rear Footwell Register |
| *21 | Front Passenger Side Rear Footwell Register | - | - |
| *a | View from *b | *b | Direction of View |
| *c | Recirculated Air | *d | Fresh Air |
| Control Damper | Operation Position | Damper Position | Operation |
|---|---|---|---|
| Air Inlet Control Damper | FRESH | A1, B1 | Allows fresh air to enter. |
| RECIRCULATION | A2, B2 | Causes internal air to recirculate. | |
| Air Mix Control Damper | - | C1 - C2 | Varies the front passenger side mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HI to LO. |
| D2 - D1 | Varies the driver side mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HI to LO. | ||
| Air Outlet Control Damper | DEF
|
F, H, K | Defrosts the windshield through the center defroster, side defrosters and side registers. |
FOOT/DEF
|
F, H, J to K | Defrosts the windshield through the center defroster and side defrosters, while air is also blown out from the front and rear footwell register ducts. In addition, air blows out slightly from the side registers and rear center register. | |
FOOT
|
E to F, H, J | Air blows out of the front and rear footwell register ducts. In addition, air blows out slightly from the center defroster, side defrosters, side registers and rear center register. | |
B/L
|
E, G to I, J to K | Air blows out of the center registers, side registers, rear center register and front and rear footwell register ducts. | |
FACE
|
E, G, K | Air blows out of the center registers, side registers and rear center register. |
Air Outlets and Airflow Volume (for Front Air Conditioning Unit Assembly)
| Mode | FACE | FOOT | DEF | |
|---|---|---|---|---|
| Center | Side | |||
| A | B | C | D | |
FACE
|
|
|
|
|
B/L
|
|
|
|
|
FOOT
|
|
|
|
|
FOOT/DEF
|
|
|
|
|
DEF
|
|
|
|
|
The size of the circle ○ indicates the proportion of airflow volume.
Mode Position and Damper Operation
| *1 | Rear Blower Motor with Fan Sub-assembly | *2 | Heater Radiator Unit Sub-assembly |
| *3 | Rear Evaporator Sub-assembly | *4 | Rear Passenger Side Side Register |
| *5 | Rear Passenger Side Footwell Register | *6 | Air Mix Control Damper |
| *7 | Mode Switching Damper | - | - |
| Control Damper | Operation Position | Damper Position | Operation |
|---|---|---|---|
| Air Mix Control Damper | - | A - B | Varies the rear passenger side mixture ratio of the air in order to regulate the temperature continuously from HI to LO. |
| Air Outlet Control Damper | FACE
|
C, F | Air blows out of the rear passenger side side register |
B/L
|
D, G | Air blows out of the rear passenger side side register and rear passenger side footwell register. | |
FOOT
|
E, H | Air blows out of the rear passenger side footwell register. |
Air Outlets and Airflow Volume (for Rear Air Conditioning Unit Assembly)
| Mode | FACE | FOOT |
|---|---|---|
| A | B | |
FACE
|
|
|
B/L
|
|
|
FOOT
|
|
|
The size of the circle ○ indicates the proportion of airflow volume.