CONSTRUCTION
Ejector Cycle System (ECS) Type No. 1 Cooler Evaporator Sub-assembly (HV models for Europe and Australia)
The ECS type No. 1 cooler evaporator sub-assembly is composed of a tank, tubes and cooling fins. For the tubes, extrusion is used so that small passages are created, helping to achieve excellent heat transmission performance and to allow for a thinner design (38 mm). In addition, reductions in the height and pitch of the fins and reductions in the thickness of the tubes are achieved, helping to promote heat transmission and to allow for thinner core materials. The result of this is a significant reduction in size and weight of the evaporator. Also, clean coat is used for the main body of the evaporator, helping to suppress development of bacteria, which may cause bad smells, and chrome-free surface treatment is used in consideration of the environment.
The ejector is positioned in the ECS type No. 1 cooler evaporator sub-assembly top tank. The flow of the refrigerant is divided into the upwind and downwind sections as it passes through the evaporator, allowing for the ejector cycle (EJECS II)*.
*: Ejector cycle (EJECS II) is a registered trademark owned by DENSO Corporation.
| *a | Top Tank | *b | Ejector |
| *c | Bottom Tank | *d | Cooling Fin |
| *e | Multiple Passage Tube | - | - |
Cold-Storage (CS) Evaporator (Gasoline models for Australia)
The cold storage evaporator is composed of tanks, tubes, cooling fins and cold storage cases.
The cold storage cases with built-in cold insulators are structures sandwiched between tubes used as refrigerant passages and can store cold energy in a short amount of time.
| *1 | Cold Insulator | *2 | Cold Storage Case |
| *3 | Tube | - | - |
| *a | A - A Cross Section | - | - |
Beneficial Refrigerant Stream (BRS) Type No. 1 Cooler Evaporator Sub-assembly (HV models for Near and Middle East or Gasoline models for Russia)
The Beneficial Refrigerant Stream (BRS) evaporator is composed of tanks, tubes and cooling fins. The tubes project outwards and are shaped as a fine duct in an attempt to offer superior conductivity with a more narrow width. Furthermore, the evaporator has been drastically miniaturized and lightened through efforts to promote conductivity through shrinking the fin height, tube thickness and fin pitch, as well as by thinning the core material.
The route that refrigerant passes through within the evaporator is optimized and pressure losses are reduced in an effort to increase performance and decrease size.
| *a | Tank | *b | Multiple Passage Tube |
| *c | Cooling Fin | - | - |
Rear Evaporator
A Revolutionary Super-slim (RS) type evaporator is used. Placing the tanks at the top and the bottom of the evaporator and using a micropore tube construction provides the following benefits:
Improved heat exchange efficiency
More uniform temperature distribution
A thinner evaporator
| *a | Tank | *b | Cooling Fin |
| *c | Tube | - | - |
OPERATION
Refrigerant Route of Beneficial Refrigerant Stream (BRS) Evaporator (HV models for Near and Middle East or Gasoline models for Russia)
While flowing through the evaporator tubes, refrigerant exchanges heat and vaporizes from a mist state.
As shown in the illustration below, the proportion of tubes through which refrigerant flows increases as the direction the refrigerant flows in changes. This makes it easier for refrigerant to flow and decreases pressure losses.
Ejector Cycle System Operation (HV models for Europe and Australia)
In a conventional refrigerant cycle, liquid refrigerant gas is sent into the cooler evaporator sub-assembly using the cooler expansion valve, generating cold air. However, a rapid decrease in the refrigerant pressure forms swirls, causing energy loss.
In this ejector cycle, the energy loss caused by the cooler expansion valve is utilized by the operation of the ejector that injects and expands a high-pressure refrigerant, thus reducing energy consumption.
Structure and Operation of Ejector (HV models for Europe and Australia)
The ejector is composed of the nozzle, mixing and diffuser sections.
A high temperature and high pressure liquid refrigerant flowing from the cooler condenser assembly is depressurized at the nozzle section and sucks in the low temperature and low pressure gaseous refrigerant from the No. 1 cooler evaporator sub-assembly on the downwind side.
The refrigerants are mixed at the mixing section, and the flow speed is decreased at the diffuser section so that the refrigerant is pressurized and flows into the No. 1 cooler evaporator sub-assembly on the upwind side. This realizes the condition where the refrigerant pressure in the No. 1 cooler evaporator sub-assembly on the downwind side is considerably lower than that on the upwind side, creating the lower temperature conditions.
Therefore, air cooled by the No. 1 cooler evaporator sub-assembly on the upwind side can be further cooled by the No. 1 cooler evaporator sub-assembly on the downwind side, thus improving the efficiency of the No. 1 cooler evaporator sub-assembly.
As a result of this, energy efficiency and cooling performance are enhanced. This allows for the reduction in the rotation speed of the electric inverter compressor, resulting in lower power consumption of the air conditioning.