The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced when repairing air leaks in the intake system are shown below.
1.INSPECT INTAKE SYSTEM
To prevent injury due to contact with an operating V-ribbed belt or cooling fan, keep your hands and clothing away from the V-ribbed belt and cooling fans when working in the engine compartment with the engine running or the ignition switch ON.
Check that there are no vacuum leaks at the points shown in the illustration.
Perform Inspection After Repair after repairing vacuum leaks in the intake system.
Click hereEngine / Hybrid System>2GR-FKS (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
2.INSPECT INTAKE AIR CONTROL VALVE (for ACIS)
| *a | Actuator Rod |
When Activate the VSV for Intake Control is set to on, check that the actuator rod operates.
| Tester Display |
|---|
| Activate the VSV for Intake Control |
If the actuator rod does not operate, inspect the intake air control valve (for ACIS) and No. 1 vacuum switching valve assembly (for ACIS).
Inspect intake air control valve (for ACIS)
Inspect No. 1 vacuum switching valve assembly (for ACIS)
Click hereEngine / Hybrid System>2GR-FKS (INTAKE / EXHAUST)>VACUUM SWITCHING VALVE (for ACIS)>INSPECTION
When Activate the VSV for Intake Control is set to off, check that the actuator rod returns to its original position.
If the actuator rod does not return to its original position, inspect the intake air control valve (for ACIS) and No. 1 vacuum switching valve assembly (for ACIS).
Inspect intake air control valve (for ACIS)
Inspect No. 1 vacuum switching valve assembly (for ACIS)
Click hereEngine / Hybrid System>2GR-FKS (INTAKE / EXHAUST)>VACUUM SWITCHING VALVE (for ACIS)>INSPECTION
3.PERFORM INITIALIZATION
Perform Inspection After Repair after repairing vacuum leaks in the intake system.
Click hereEngine / Hybrid System>2GR-FKS (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION