Home › General › MAINTENANCE › A25A-FXS AIR CLEANER FILTER ELEMENT
RM37A0E _V1 General _086848 MAINTENANCE _0416463 A25A-FXS AIR CLEANER FILTER ELEMENT A

MAINTENANCE  A25A-FXS AIR CLEANER FILTER ELEMENT  REMOVAL  


PROCEDURE

Hide 17705 1.SEPARATE AIR CLEANER CAP SUB-ASSEMBLY

a.
A455261C01
2.781,1.844 3,2.021 0.219,0.177 10 true *b 1.729,1.833 1.948,2.01 0.219,0.177 10 true *b 1.74,0.438 1.948,0.604 0.208,0.167 10 true *a 2.781,0.427 2.99,0.594 0.208,0.167 10 true *a
*a Air Cleaner Cap Clamp
*b Guide


Disengage the 2 air cleaner cap clamps.


b.

Disengage the 2 guides to separate the air cleaner cap sub-assembly from the air cleaner case sub-assembly.


Hide 17801 2.REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

a.
A455262

Remove the air cleaner filter element sub-assembly from the air cleaner case sub-assembly.

NOTICE:

Do not allow foreign matter to enter the air cleaner cap sub-assembly and air cleaner case sub-assembly.



Hide 17801 3.INSPECT AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

HINT:

This procedure is only performed when the air cleaner filter element sub-assembly will be reused.


a.

Check whether the air cleaner filter element sub-assembly is dirty or clogged.


b.
A376850C02
1.698,0.542 2.135,0.542 true 2.177,0.458 2.396,0.688 0.219,0.229 10 false *a
*a Air Cleaner Filter Element Sub-assembly Intake Downstream Side (Air Cleaner Cap Sub-assembly Side)


If the air cleaner filter element sub-assembly is dirty or has foreign matter adhered to it, clean the air cleaner filter element sub-assembly with compressed air.

NOTICE:

When cleaning the air cleaner filter element sub-assembly, blow the compressed air from the intake downstream side (from the air cleaner cap sub-assembly side).


HINT:

If the air cleaner filter element sub-assembly is still extremely dirty after cleaning it, replace the air cleaner filter element sub-assembly with a new one.