Home › Engine / Hybrid System › A25A-FXS, A25B-FXS (EMISSION CONTROL) › PURGE VALVE
RM37A0E _51 Engine / Hybrid System _086908 A25A-FXS EMISSION CONTROL _0416575 PURGE VALVE G

A25A-FXS EMISSION CONTROL  PURGE VALVE  INSPECTION  


PROCEDURE

Hide 25860 1.INSPECT PURGE VALVE (PURGE VSV)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω


If the result is not as specified, replace the purge valve (purge VSV).


b.
A457808C01
1.375,1.781 1.375,1.354 true 0.74,1.229 0.583,0.698 0.583,0.698 0.365,0.698 true 1.323,1.813 1.563,2.083 0.24,0.271 10 false *a 0.177,0.604 0.531,0.917 0.354,0.313 10 false *b 2.052,1.958 2.302,2.146 0.25,0.188 10 false *c 2.365,0.021 2.865,0.781 0.5,0.76 10 false *d
*a Port (E)
*b Port (F)
*c Air
*d Component without harness connected
(Purge Valve (Purge VSV))


Apply auxiliary battery voltage between the terminals of the purge valve (purge VSV) and check that the following occurs when blowing air into the port (E).

OK:
Measurement Condition Specified Condition
Auxiliary battery voltage applied between terminals 1 and 2 Air flows from port (F)
Auxiliary battery voltage not applied between terminals 1 and 2 Air does not flow


If the result is not as specified, replace the purge valve (purge VSV).