LIGHTING (EXT)  RELAY  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 85960D 1.INSPECT H-LP RH RELAY

a.
E367719N01
1.146,0.948 1.313,0.49 false 1.281,1.771 1.125,1.333 false 0.802,0.99 0.969,0.531 false 0.719,1.719 0.563,1.281 false 1.323,0.302 1.635,0.5 0.313,0.198 10 false 1 1.292,1.771 1.604,1.969 0.313,0.198 10 false 2 0.969,0.344 1.281,0.542 0.313,0.198 10 false 5 0.719,1.74 1.031,1.938 0.313,0.198 10 false 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the H-LP RH relay.


Hide 85960E 2.INSPECT H-LP LH RELAY

a.
E367719N01
1.146,0.948 1.313,0.49 false 1.281,1.771 1.125,1.333 false 0.802,0.99 0.969,0.531 false 0.719,1.719 0.563,1.281 false 1.323,0.302 1.635,0.5 0.313,0.198 10 false 1 1.292,1.771 1.604,1.969 0.313,0.198 10 false 2 0.969,0.344 1.281,0.542 0.313,0.198 10 false 5 0.719,1.74 1.031,1.938 0.313,0.198 10 false 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the H-LP LH relay.


Hide 85926 3.INSPECT DIMMER RELAY

a.
E367719N01
1.146,0.948 1.313,0.49 false 1.281,1.771 1.125,1.333 false 0.802,0.99 0.969,0.531 false 0.719,1.719 0.563,1.281 false 1.323,0.302 1.635,0.5 0.313,0.198 10 false 1 1.292,1.771 1.604,1.969 0.313,0.198 10 false 2 0.969,0.344 1.281,0.542 0.313,0.198 10 false 5 0.719,1.74 1.031,1.938 0.313,0.198 10 false 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the DIMMER relay.


Hide 82642B 4.INSPECT DRL RELAY

a.
E367719N01
1.146,0.948 1.313,0.49 false 1.281,1.771 1.125,1.333 false 0.802,0.99 0.969,0.531 false 0.719,1.719 0.563,1.281 false 1.323,0.302 1.635,0.5 0.313,0.198 10 false 1 1.292,1.771 1.604,1.969 0.313,0.198 10 false 2 0.969,0.344 1.281,0.542 0.313,0.198 10 false 5 0.719,1.74 1.031,1.938 0.313,0.198 10 false 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the DRL relay.


Hide 85916D 5.INSPECT FR FOG RELAY

a.
E367719N01
1.146,0.948 1.313,0.49 false 1.281,1.771 1.125,1.333 false 0.802,0.99 0.969,0.531 false 0.719,1.719 0.563,1.281 false 1.323,0.302 1.635,0.5 0.313,0.198 10 false 1 1.292,1.771 1.604,1.969 0.313,0.198 10 false 2 0.969,0.344 1.281,0.542 0.313,0.198 10 false 5 0.719,1.74 1.031,1.938 0.313,0.198 10 false 3

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
3 - 5 Voltage not applied between terminals 1 and 2 10 kΩ or higher
3 - 5 Voltage applied between terminals 1 and 2 Below 1 Ω


If the result is not as specified, replace the FR FOG relay.