Home › Vehicle Exterior › WINDOW / GLASS › WINDOW DEFOGGER SYSTEM
RM37A0E _59 Vehicle Exterior _086899 WINDOW / GLASS _0416697 WINDOW DEFOGGER SYSTEM D

WINDOW / GLASS  WINDOW DEFOGGER SYSTEM  DIAGNOSIS SYSTEM  



INSPECT AUXILIARY BATTERY VOLTAGE


a.

Measure the auxiliary battery voltage with the ignition switch off.*1


b.

Measure the auxiliary battery voltage.*2

*1: for HV Model

*2: for Gasoline Model


Standard Voltage:

11 to 14 V


If the voltage is below 11 V, recharge or replace the auxiliary battery.