88719A
1.INSPECT AIR CONDITIONER PRESSURE SENSOR
Check the wire harness.
Disconnect the A24 air conditioner pressure sensor connector.
Disconnect the H63 air conditioning amplifier assembly connector.
| *a | Front view of wire harness connector
(Air Conditioner Pressure Sensor) |
| *b | Front view of wire harness connector
(Air Conditioning Amplifier Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-1 (-) - H63-15 (SG-4) | Always | Below 1 Ω |
| A24-2 (PR) - H63-6 (PRE) | Always | Below 1 Ω |
| A24-3 (+) - H63-11 (S5-3) | Always | Below 1 Ω |
| A24-1 (-) or H63-15 (SG-4) - Other terminals and body ground | Always | 10 kΩ or higher |
| A24-2 (PR) or H63-6 (PRE) - Other terminals and body ground | Always | 10 kΩ or higher |
| A24-3 (+) or H63-11 (S5-3) - Other terminals and body ground | Always | 10 kΩ or higher |
If the resistance is not as specified, repair or replace the wire harness.
Connect the H63 air conditioning amplifier assembly connector.
Turn the ignition switch to ON.
| *a | Front view of wire harness connector
(Air Conditioner Pressure Sensor) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-3 (+) - Body ground | Ignition switch on (IG) | 4.75 to 5.25 V |
If the result is not as specified, repair or replace the wire harness or replace the air conditioning amplifier assembly.
Check the air conditioner pressure sensor.
Connect the A24 air conditioner pressure sensor connector.
Install a manifold gauge set.
Turn the A/C switch on.
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
Check from the rear of the connector while it is connected to the air conditioning amplifier assembly.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-6 (PRE) - H63-15 (SG-4) | Refrigerant pressure: Normal pressure (less than 3025 kPa (30.8 kgf/cm2, 439 psi) and more than 176 kPa (1.8 kgf/cm2, 26 psi)) | 0.74 to 4.61 V |
If the voltage is not as specified, replace the air conditioner pressure sensor.