SPECIFICATIONS  HYBRID / BATTERY CONTROL  SERVICE DATA  


Reserve Tank Cap (for Inverter)
Item Specified Condition
Standard Value (for Brand-new Cap) 94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)
Minimum Standard Value (for Used Cap) 94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
Item Tester Connection Specified Condition
IGCT Relay (IGCT)
Resistance
3 - 5 10 kΩ or higher
Auxiliary battery voltage not applied between terminals 1 and 2
Below 1 Ω
Auxiliary battery voltage applied between terminals 1 and 2

HV Battery Junction Block Assembly
SMRB
Resistance
z22-1 (+) - Y3-1 (CBI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M32-1 (SMRB) and M32-3 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals M32-1 (SMRB) and M32-3 (GND)
M32-1 (SMRB) - M32-3 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRG
Resistance
z21-1 (-) - Y4-1 (CEI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M32-4 (SMRG) and M32-3 (GND)
Below 1 Ω
Auxiliary battery voltage applied between terminals M32-4 (SMRG) and M32-3 (GND)
M32-4 (SMRG) - M32-3 (GND) 25.0 to 59.0 Ω at -40 to 80°C (-40 to 176°F)
SMRP
Resistance
z21-1 (-) - Y4-1 (CEI) 10 kΩ or higher
Auxiliary battery voltage not applied between terminals M32-2 (SMRP) and M32-3 (GND)
24.3 to 29.7 Ω
Auxiliary battery voltage applied between terminals M32-2 (SMRP) and M32-3 (GND)
M32-2 (SMRP) - M32-3 (GND) 140 to 290 Ω at -40 to 80°C (-40 to 176°F)

EV Drive Mode Switch (Pattern Select Switch Assembly)
EV Drive Mode Switch (Pattern Select Switch Assembly)
Resistance
P9-5 (S) - P9-2 (E) Below 1 Ω
EV drive mode switch (pattern select switch assembly) being pushed and held
10 kΩ or higher
EV drive mode switch (pattern select switch assembly) not pushed
EV Drive Mode Switch (Pattern Select Switch Assembly)
Illumination
Battery positive (+) → P9-6 (ILL+)
Battery negative (-) →P9-1 (ILL-)
Illuminates

Trail Switch (Pattern Select Switch)
Trail Switch (Pattern Select Switch)
Resistance
P8-5 (B) - P8-2 (E) Below 1 Ω
Trail switch (pattern select switch) being pushed and held
10 kΩ or higher
Trail switch (pattern select switch) not pushed
Trail Switch (Pattern Select Switch)
Illumination
Battery positive (+) → P8-6 (ILL+)
Battery negative (-) →P8-1 (ILL-)
Illuminates

Drive Mode Select Switch (No. 1 Pattern Select Switch Assembly)
Drive Mode Select Switch (No. 1 Pattern Select Switch Assembly)
Resistance
P3-7 (SEL) - P3-5 (E) Below 50 Ω
Pushed and held at "DRIVE +" side
10 kΩ or higher
Released (neutral position)
P3-6 (E) - P3-5 (E) Below 50 Ω
Pushed and held at "DRIVE -" side
10 kΩ or higher
Released (neutral position)
Drive Mode Select Switch (No. 1 Pattern Select Switch Assembly)
Illumination
Auxiliary battery positive (+) → P3-1 (ILL+)
Auxiliary battery negative (-) → P3-4 (ILL-)
Illuminates

Service Plug Grip
Tester Connection Condition Specified Condition
Service Plug Grip Always Below 1 Ω

Hybrid Battery Terminal Block
Hybrid Battery Terminal Block Always Below 1 Ω