87510S
1.INSPECT SEAT HEATER ASSEMBLY
| *a | Component without harness connected
(Seat Heater Assembly (for LH Side)) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Seat heater temperature 20 °C (68 °F) | 3.36 to 4.02 Ω |
If the result is not as specified, replace the seat heater assembly (for LH side).