85912R
1.INSPECT S/HTR F/L RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the S/HTR F/L relay.
85912Q
2.INSPECT S/HTR F/R RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the S/HTR F/R relay.
85911S
3.INSPECT S/HTR R/L RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the S/HTR R/L relay.
85911R
4.INSPECT S/HTR R/R RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Auxiliary battery voltage applied between terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Auxiliary battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the S/HTR R/R relay.