Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › ULTRASONIC SENSOR (for Front)
RM37A0E _56 Audio / Visual / Telematics _086880 PARK ASSIST / MONITORING _0417849 ULTRASONIC SENSOR(for Front) G

PARK ASSIST / MONITORING  ULTRASONIC SENSOR(for Front)  INSPECTION  


PROCEDURE

Hide 89341L 1.INSPECT FRONT CENTER ULTRASONIC SENSOR

a.
E388203C20
1.917,0.979 2.219,0.51 true 1.708,0.969 1.521,0.458 true 1.51,0.969 1.063,0.531 true 1.167,1.698 1.479,1.281 true 1.646,1.729 1.708,1.292 true 2.208,1.688 1.927,1.292 true 0.104,0.135 0.417,0.292 0.313,0.156 10 false *a 0.854,0.396 1.167,0.594 0.313,0.198 10 false EO 1.417,0.302 1.729,0.5 0.313,0.198 10 false SO 2.208,0.354 2.521,0.552 0.313,0.198 10 false BO 1.063,1.729 1.375,1.927 0.313,0.198 10 false EI 2.198,1.719 2.51,1.917 0.313,0.198 10 false BI 1.583,1.76 1.896,1.958 0.313,0.198 10 false SI
*a Component without harness connected
(Front Center Ultrasonic Sensor)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (BI) - 6 (EI) Always 10 kΩ or higher
4 (BI) - 1 (BO) Always Below 1 Ω
5 (SI) - 2 (SO) Always Below 30 Ω
6 (EI) - 3 (EO) Always Below 1 Ω


If the result is not as specified, replace the front center ultrasonic sensor.


Hide 89341K 2.INSPECT FRONT CORNER ULTRASONIC SENSOR

a.

for LH Side:

i.
E388203C20
1.917,0.979 2.219,0.51 true 1.708,0.969 1.521,0.458 true 1.51,0.969 1.063,0.531 true 1.167,1.698 1.479,1.281 true 1.646,1.729 1.708,1.292 true 2.208,1.688 1.927,1.292 true 0.104,0.135 0.417,0.292 0.313,0.156 10 false *a 0.854,0.396 1.167,0.594 0.313,0.198 10 false EO 1.417,0.302 1.729,0.5 0.313,0.198 10 false SO 2.208,0.354 2.521,0.552 0.313,0.198 10 false BO 1.063,1.729 1.375,1.927 0.313,0.198 10 false EI 2.198,1.719 2.51,1.917 0.313,0.198 10 false BI 1.583,1.76 1.896,1.958 0.313,0.198 10 false SI
*a Component without harness connected
(Front Corner Ultrasonic Sensor LH)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (BI) - 6 (EI) Always 10 kΩ or higher
4 (BI) - 1 (BO) Always Below 1 Ω
5 (SI) - 2 (SO) Always Below 30 Ω
6 (EI) - 3 (EO) Always Below 1 Ω


If the result is not as specified, replace the front corner ultrasonic sensor LH.



b.

for RH Side:

i.
E388203C21
1.167,1.698 1.479,1.281 true 1.646,1.729 1.708,1.292 true 2.208,1.688 1.927,1.292 true 0.104,0.135 0.417,0.292 0.313,0.156 10 false *a 1.063,1.729 1.375,1.927 0.313,0.198 10 false EI 2.198,1.719 2.51,1.917 0.313,0.198 10 false BI 1.583,1.76 1.896,1.958 0.313,0.198 10 false SI
*a Component without harness connected
(Front Corner Ultrasonic Sensor RH)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (BI) - 6 (EI) Always 10 kΩ or higher
4 (BI) - 1 Always Below 1 Ω
5 (SI) - 2 Always Below 30 Ω
6 (EI) - 3 Always Below 1 Ω


If the result is not as specified, replace the front corner ultrasonic sensor RH.