Home › General › SPECIFICATIONS › 2GR-FKS ENGINE CONTROL
RM37A0E _V1 General _086915 SPECIFICATIONS _0415867 2GR-FKS ENGINE CONTROL F

SPECIFICATIONS  2GR-FKS ENGINE CONTROL  SERVICE DATA  


IGNITION SYSTEM
Standard Insulation Resistance Spark plug (terminal part) - Body ground 10 MΩ or higher
Spark Plug Type DENSO made FK20HBR8
Maximum Electrode Gap for Used Spark Plug 1.1 mm (0.0433 in.)
Standard Electrode Gap for New Spark Plug 0.7 to 0.8 mm (0.0276 to 0.0315 in.)

CAMSHAFT OIL CONTROL VALVE
Standard Stroke for Intake Side 4.5 mm (0.177 in.) or more
for Exhaust Side 2.2 mm (0.0866 in.) or more

CAMSHAFT OIL CONTROL SOLENOID
Standard Resistance 1 - 2 0°C (32°F) 5.3 to 6.3 Ω
20°C (68°F) 5.8 to 6.8 Ω
40°C (104°F) 6.2 to 7.4 Ω
Stroke Amount Standard 6.5 mm (0.256 in.) or more

THROTTLE BODY
Standard Resistance 1 (M-) - 2 (M+) 20°C (68°F) 0.3 to 100 Ω

VACUUM SWITCHING VALVE (for Engine Mounting)
Standard Resistance 1 - 2 20°C (68°F) 37 to 44 Ω
1 - Body ground 10 kΩ or higher
2 - Body ground 10 kΩ or higher

MASS AIR FLOW METER
Standard Resistance 4 (THA) - 2 (E2G) Always 0.47 to 19.3 kΩ

ENGINE COOLANT TEMPERATURE SENSOR
Standard Resistance 20°C (68°F) 2.32 to 2.59 kΩ
80°C (176°F) 0.310 to 0.326 kΩ

KNOCK SENSOR
Standard Resistance 25°C (77°F) 120 to 280 kΩ

AIR FUEL RATIO SENSOR
Standard Resistance
Air Fuel Ratio Sensor (for Bank 1)
1 (HA1A) - 2 (+B) 20°C (68°F) 1.6 to 3.2 Ω
1 (HA1A) - 4 (A1A-) Always 10 kΩ or higher
Standard Resistance
Air Fuel Ratio Sensor (for Bank 2)
1 (HA2A) - 2 (+B) 20°C (68°F) 1.6 to 3.2 Ω
1 (HA2A) - 4 (A2A-) Always 10 kΩ or higher

HEATED OXYGEN SENSOR
Standard Resistance
Heated Oxygen Sensor (for Bank 1)
1 (HT1B) - 2 (+B) 20°C (68°F) 5 to 10 Ω
1 (HT1B) - 4 (E2) Always 10 kΩ or higher
Standard Resistance
Heated Oxygen Sensor (for Bank 2)
1 (HT2B) - 2 (+B) 20°C (68°F) 5 to 10 Ω
1 (HT2B) - 4 (E2) Always 10 kΩ or higher

RELAY
Standard Resistance
(No. 1 Electronic Fuel Injection Main Relay (EFI-MAIN))
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
(Air Fuel Ratio Sensor Heater Relay (A/F HTR))
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
(Fuel Pump Relay (FUEL PMP))
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
(Injection Relay (D INJ))
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω
Standard Resistance
No. 2 ignition relay (IG2 NO. 1)
3 - 5 Battery voltage not applied between terminals 1 and 2 10 kΩ or higher
Battery voltage applied between terminals 1 and 2 Below 1 Ω