Home › Engine / Hybrid System › A25A-FXS, A25B-FXS (COOLING) › FLOW SHUTTING VALVE
RM37A0E _51 Engine / Hybrid System _086910 A25A-FXS, A25B-FXS COOLING _0419154 FLOW SHUTTING VALVE G

A25A-FXS, A25B-FXS COOLING  FLOW SHUTTING VALVE  INSPECTION  


PROCEDURE

Hide 16260 1.INSPECT FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)

a.
A401655C04
0.052,0.042 0.458,0.323 0.406,0.281 10 false *a
*a Component without harness connected
(Flow Shutting Valve (Water By-pass Hose Assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 22 to 28 Ω


If the result is not as specified, replace the flow shutting valve (water by-pass hose assembly).