A25A-FXS, A25B-FXS BATTERY / CHARGING  CHARGING SYSTEM  DIAGNOSIS SYSTEM  


DLC3 (Data Link Connector 3)




AUXILIARY BATTERY VOLTAGE


Standard Voltage:
Switch Condition Specified Condition
Ignition switch ON 11 to 14 V


If voltage is below 11 V, recharge or replace the auxiliary battery.

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.