DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Chassis / EMPS / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Meter Vehicle Velocity | Vehicle speed from speedometer | Min.: 0.0 km/h (0.0 MPH)
Max.: 300.0 km/h (186.4 MPH) |
·
0 km/h (0 MPH): Engine running and vehicle stopped ·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| Wheel Speed Right | Rear right wheel speed | Min.: 0 km/h (0 MPH)
Max.: 255 km/h (158 MPH) |
·
0 km/h (0 MPH): Engine running and vehicle stopped ·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| Wheel Speed Left | Rear left wheel speed | Min.: 0 km/h (0 MPH)
Max.: 255 km/h (158 MPH) |
·
0 km/h (0 MPH): Engine running and vehicle stopped ·
No significant fluctuation: Engine running and vehicle driven at a constant speed |
- |
| Engine/Power Management ECU Pseudo Engine Revolution | Engine speed | Min.: 0 rpm
Max.: 12800 rpm |
No significant fluctuation | Engine running at a constant speed |
| Motor Actual Current | Amount of current to motor | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort
- The value increases when turning right and decreases when turning left |
Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Command Value Current | Requested current to motor | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort
- The value increases when turning right and decreases when turning left |
Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Steering Angle Velocity | Steering angle speed | Min.: -32768 deg/s
Max.: 32767 deg/s |
Value changes in proportion to steering speed
- The value increases when turning left and decreases when turning right |
Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Thermistor Temperature | ECU substrate temperature | Min.: -50.0°C (-58.0°F)
Max.: 150.0°C (302.0°F) |
-50°C to 150°C (-58°F to 302°F) | - |
| IG Power Supply | IG power source voltage | Min.: 0.0000 V
Max.: 20.1531 V |
8 to 16 V | Ignition switch ON |
| Steering Angle Sens Sig | Steering sensor signal state | OK or NG(1) or NG(2) or NG(3) | OK: Steering sensor signal received
NG(1): The learning has not completed NG(2): Steering sensor abnormal NG(3): Communication error |
- |
| Steering Wheel Torque | Steering wheel torque | Min.: -7.00 Nm
Max.: 7.00 Nm |
Value changes in proportion to steering effort
- The value increases when turning left and decreases when turning right |
Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor Rotation Angle | Motor rotation angle | Min.: 0.000 deg
Max.: 360.000 deg |
During steering operation, motor rotation angle value changes from 0 to 360° | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Command Val Current 2 | Requested current to motor | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor Voltage | Motor power supply voltage | Min.: 0.000 V
Max.: 98.000 V |
9 to 16 V | Always |
| TRQ1 Zero Point Value | Zero point value of torque sensor 1 | Min.: 0.0000 V
Max.: 4.9725 V |
2.3 to 2.7 V | Engine running and steering wheel not being turned (without load)*1
Hybrid control system started and steering wheel not being turned (without load)*2 |
| TRQ2 Zero Point Value | Zero point value of torque sensor 2 | Min.: 0.0000 V
Max.: 4.9725 V |
2.3 to 2.7 V | Engine running and steering wheel not being turned (without load)*1
Hybrid control system started and steering wheel not being turned (without load)*2 |
| IG ON/OFF Times | Number of times of ignition switch turned on/off since latest DTC detection | Min.: 0 times
Max.: 65535 times |
- | - |
| Motor Overheat Record | Continuous overheat prevention control record | Unrec or Rec | Unrec | Unrec: Unrecorded
Rec: Recorded The amount of power assist may be decreased to prevent the motor and ECUs from overheating if the steering wheel is continuously turned when the vehicle is either stopped or driven at a low speed, or if the steering wheel is kept in either full lock position for a long time. |
| Motor Lo Power Record | PIG power source voltage drop record | Unrec or Rec | Unrec | Unrec: Unrecorded
Rec: Recorded If the PIG power source voltage decreases temporarily, the amount of power assist will be reduced. |
| Eng Rev/System Start Inter Record | Record of engine signal interruption | Unrec or Rec | Unrec | Unrec: Unrecorded
Rec: Recorded |
| Str Angle Inter Record | Record of steering sensor signal interruption occurrence display | Unrec or Rec | Unrec | Unrec: Unrecorded
Rec: Recorded |
| Spd Sig Invalid Record | Record of vehicle speed signal invalid | Unrec or Rec | Unrec | Unrec: Unrecorded
Rec: Recorded |
| Battery Voltage Lo Record | Auxiliary battery voltage reduction history | Min.: 0 times
Max.: 65535 times |
0 to 65535 times | - |
| Battery Control Count (Body ECU) | Number of auxiliary battery load control operations | Min.: 0 times
Max.: 65535 times |
- | - |
| PS Assist Signal | Status of the record of power steering assist signal | OFF or ON | for Gasoline Model:
OFF: Ignition switch ON ON: Engine running for HV Model: OFF: Ignition switch ON ON: Ignition switch ON (READY) |
- |
| Ready Status | Ready status | OFF or Ready | OFF: Except ignition switch ON (READY)
Ready: Ignition switch ON (READY) |
*2 |
| Motor Actual Current 2 | Amount of current to motor | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor Overheat Limit Cnt(Normal) | Number of times that assist limit was performed according to the estimated temperature of the motor coil and heat generating components of the power steering ECU assembly | Min.: 0 times
Max.: 255 times |
- | - |
| Current Key Cycle | Number of times that ignition switch was turned to ON | Min.: 0 times
Max.: 65535 times |
- | - |
| Current Key Cycle Elapsed Time | Time elapsed since ignition switch was turned to ON | Min.: 0.0 s
Max.: 53687091.1 s |
- | - |
| Steering Angle | Steering angle | Min.: -3072.0 deg
Max.: 3070.5 deg |
- | - |
| Torque Sensor 1 Output | Torque sensor 1 output value | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Torque Sensor 2 Output | Torque sensor 2 output value | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Torque Sensor 1 Power Supply | Torque sensor 1 power supply voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Torque Sensor 2 Power Supply | Torque sensor 2 power supply voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Rotation Angle Sensor Output 1 | Rotation angle sensor Vx1 output voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Rotation Angle Sensor Output 2 | Rotation angle sensor Vx2 output voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Rotation Angle Sensor Output 3 | Rotation angle sensor Vy1 output voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Rotation Angle Sensor Output 4 | Rotation angle sensor Vy2 output voltage | Min.: 0.0000 V
Max.: 4.9725 V |
- | - |
| Motor 1 Terminal Current (U) | Motor 1 terminal current (U phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 1 Terminal Current (V) | Motor 1 terminal current (V phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 1 Terminal Current (W) | Motor 1 terminal current (W phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 2 Terminal Current (U) | Motor 2 terminal current (U phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 2 Terminal Current (V) | Motor 2 terminal current (V phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 2 Terminal Current (W) | Motor 2 terminal current (W phase) | Min.: -327.68 A
Max.: 327.67 A |
Value changes in proportion to steering effort | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 1 U Phase Duty | Motor 1 U phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 1 V Phase Duty | Motor 1 V phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 1 W Phase Duty | Motor 1 W phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 2 U Phase Duty | Motor 2 U phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 2 V Phase Duty | Motor 2 V phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 2 W Phase Duty | Motor 2 W phase duty | Min.: 0.00%
Max.: 100.00% |
- | - |
| Motor 1 Terminal Volt (U) | Motor 1 terminal voltage (U phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4 to 35 V range | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 1 Terminal Volt (V) | Motor 1 terminal voltage (V phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4 to 35 V range | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 1 Terminal Volt (W) | Motor 1 terminal voltage (W phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4 to 35 V range | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 2 Terminal Volt (U) | Motor 2 terminal voltage (U phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4 to 35 V range | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 2 Terminal Volt (V) | Motor 2 terminal voltage (V phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4 to 35 V range | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 2 Terminal Volt (W) | Motor 2 terminal voltage (W phase) | Min.: 0.000 V
Max.: 98.000 V |
Value changes within 4 to 35 V range | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 1 PIG Power Supply | Power supply voltage to active motor 1 | Min.: 0.0000 V
Max.: 20.1531 V |
9 to 16 V | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| Motor 2 PIG Power Supply | Power supply voltage to active motor 2 | Min.: 0.0000 V
Max.: 20.1531 V |
9 to 16 V | Engine running and steering wheel being turned*1
Hybrid control system started and steering wheel being turned*2 |
| The Number of DTCs | Number of detected DTCs when freeze frame data was stored | Min.: 0
Max.: 255 |
0 to 255 | - |
*1: for Gasoline model
*2: for HV model
With the vehicle stopped or driving very slowly, if the steering wheel is turned repeatedly or turned to a lock position and the vehicle is driven for an extended period of time, the amount of power assist is decreased to prevent overheating of the motor and ECU. If this occurs, engine running and do not turn the steering wheel for approximately 10 minutes to improve power assist.
If the auxiliary battery is not sufficiently charged or the voltage decreases temporarily, the amount of power assist is reduced and the EPS warning light comes on. In such cases, the amount of power assist returns to normal when the auxiliary battery voltage recovers.