MAINTENANCE  2GR-FKS BATTERY  INSTALLATION  


PROCEDURE

Hide 1.INSTALL BATTERY

a.

Install the battery to the vehicle.


b.
A454730

Install the No. 2 battery clamp to the battery clamp sub-assembly with the bolt.

Torque:
18.5 N*m (189 kgf*cm, 14 ft.*lbf)


c.

Connect the cable to the positive (+) battery terminal and tighten the nut.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


d.

Engage the 2 claws to install the battery terminal cap to the positive (+) battery terminal.


Hide 2.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

a.

Connect the cable to the negative (-) battery terminal and tighten the nut.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION