Home › General › SPECIFICATIONS › 2GR-FKS BATTERY / CHARGING
RM37A0E _V1 General _086915 SPECIFICATIONS _0415876 2GR-FKS BATTERY / CHARGING F

SPECIFICATIONS  2GR-FKS BATTERY / CHARGING  SERVICE DATA  


Battery Standard specific gravity 1.25 or more at 20°C (68°F)
Standard voltage more than 12.3 V at 20°C (68°F)
Fuse Standard resistance Below 1 Ω
Charging circuit without load Standard current 10 A or more
Standard voltage 13.2 to 14.8 V
Charging circuit with load Standard voltage 30 A or more

Generator Brush Holder Assembly
Brush length Standard exposed brush length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed brush length 4.5 mm (0.177 in.)

Generator Rotor Assembly
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.9 to 2.3 Ω
Slip ring - Rotor Always 1 MΩ or higher
Slip ring diameter Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14.0 mm (0.551 in.)