G9031A
1.INSTALL HV WATER PUMP BRACKET SUB-ASSEMBLY
Perform this procedure only when replacement of the HV water pump bracket sub-assembly is necessary.
Install the HV water pump bracket sub-assembly to the front side member sub-assembly with the 2 bolts.
G9040
2.INSTALL INVERTER WATER PUMP ASSEMBLY
Temporarily install the inverter water pump assembly to the HV water pump bracket sub-assembly with the 2 bolts.
If the inverter water pump assembly has been struck or dropped, replace it.
Do not insert at an angle.
Fully tighten the 2 bolts.
Connect the inverter water pump assembly connector.
If a dustproof cap is installed to the inverter water pump assembly connector, do not remove it until the connector is to be connected.
| *1 | No. 2 Inverter Cooling Hose |
| *2 | No. 3 Inverter Cooling Hose |
| *a | Alignment Mark |
| *b | Rib |
| *c | 2 to 7 mm (0.0787 to 0.276 in.) |
| *d | Up |
| *e | LH Side |
Connect the No. 2 inverter cooling hose and No. 3 inverter cooling hose to the inverter water pump assembly and slide the 2 clips to secure them.
Make sure to align the alignment marks of the hoses with the ribs of the inverter water pump assembly.
To prevent foreign matter from entering the inverter water pump assembly and inverter cooling system, do not remove the pieces of cloth from the pipes and disconnected hoses until installation.
Do not apply excessive force to the hoses.
Make sure that the clips are positioned as shown in the illustration.
3.ADD COOLANT (for Inverter)
4.INSPECT FOR COOLANT LEAK (for Inverter)