Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › WATER PUMP WITH MOTOR
RM37A0E _51 Engine / Hybrid System _086850 HYBRID / BATTERY CONTROL _0420001 WATER PUMP WITH MOTOR A

HYBRID / BATTERY CONTROL  WATER PUMP WITH MOTOR  INSTALLATION  


PROCEDURE

Hide G9031A 1.INSTALL HV WATER PUMP BRACKET SUB-ASSEMBLY

HINT:

Perform this procedure only when replacement of the HV water pump bracket sub-assembly is necessary.


a.

Install the HV water pump bracket sub-assembly to the front side member sub-assembly with the 2 bolts.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


Hide G9040 2.INSTALL INVERTER WATER PUMP ASSEMBLY

a.

Temporarily install the inverter water pump assembly to the HV water pump bracket sub-assembly with the 2 bolts.

NOTICE:
·

If the inverter water pump assembly has been struck or dropped, replace it.

·

Do not insert at an angle.




b.

Fully tighten the 2 bolts.

Torque:
7.0 N*m (71 kgf*cm, 62 in.*lbf)


c.

Connect the inverter water pump assembly connector.

NOTICE:

If a dustproof cap is installed to the inverter water pump assembly connector, do not remove it until the connector is to be connected.



d.
A455502C01
2.188,4.198 2.354,4.198 2.354,4.198 2.604,3.948 true 2.427,3.552 2.594,3.552 2.594,3.552 2.698,3.917 true 2.813,1.229 2.646,1.229 2.646,1.229 2.563,0.979 true 2.063,0.51 2.229,0.51 2.229,0.51 2.552,0.823 true 1.781,0.146 1.948,0.323 0.167,0.177 10 true *1 0.5,3.344 0.677,3.531 0.177,0.188 10 true *2 1.906,0.417 2.323,0.75 0.417,0.333 10 false *a 1.958,0.74 2.292,1.073 0.333,0.333 10 false *c 0.5,4 0.75,4.198 0.25,0.198 10 false *e 2.833,1.125 3.083,1.375 0.25,0.25 10 false *b 2.542,4.365 2.792,4.615 0.25,0.25 10 false *c 1.052,3.375 1.292,3.573 0.24,0.198 10 false *d 1.438,3.635 1.938,3.885 0.5,0.25 10 false 120° 2.031,4.094 2.448,4.427 0.417,0.333 10 false *a 2.25,3.458 2.5,3.708 0.25,0.25 10 false *b
*1 No. 2 Inverter Cooling Hose
*2 No. 3 Inverter Cooling Hose
*a Alignment Mark
*b Rib
*c 2 to 7 mm (0.0787 to 0.276 in.)
*d Up
*e LH Side


Connect the No. 2 inverter cooling hose and No. 3 inverter cooling hose to the inverter water pump assembly and slide the 2 clips to secure them.

NOTICE:
·

Make sure to align the alignment marks of the hoses with the ribs of the inverter water pump assembly.

·

To prevent foreign matter from entering the inverter water pump assembly and inverter cooling system, do not remove the pieces of cloth from the pipes and disconnected hoses until installation.

·

Do not apply excessive force to the hoses.



HINT:

Make sure that the clips are positioned as shown in the illustration.



Hide 3.ADD COOLANT (for Inverter)