Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HV RELAY ASSEMBLY
RM37A0E _51 Engine / Hybrid System _086850 HYBRID / BATTERY CONTROL _0420006 HV RELAY ASSEMBLY G

HYBRID / BATTERY CONTROL  HV RELAY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 1.INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY

a.

Inspect SMRB:

i.

Measure the resistance according to the value(s) in the table below.

C384277C40
3.76,1.031 4.115,1.24 0.354,0.208 5.625,0.146 6.031,0.375 0.406,0.229 3.302,0.146 3.656,0.365 0.354,0.219 3.125,1.406 3.396,1.24 true 3.792,1.417 3.625,1.24 true 3.771,0.427 3.396,0.677 true 6.292,0.698 5.802,0.698 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.063 4.281,1.26 0.458,0.198 10 false M56 2.958,1.438 3.292,1.646 0.333,0.208 10 true GND 3.677,1.417 4.156,1.625 0.479,0.208 10 true SMRB 5.688,0.167 6,0.365 0.313,0.198 10 true z11 6.323,0.604 6.479,0.802 0.156,0.198 10 false + 3.375,0.188 3.583,0.333 0.208,0.146 10 true k2 3.813,0.344 4.198,0.563 0.385,0.219 10 false CBI
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z11-1 (+) - k2-1 (CBI) Auxiliary battery voltage not applied between terminals M56-1 (SMRB) and M56-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M56-1 (SMRB) and M56-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M56-1 (SMRB) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω


If the result is not as specified, replace the HV battery junction block assembly.



b.

Inspect SMRG:

i.

Measure the resistance according to the value(s) in the table below.

C384277C41
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.469,1.479 3.427,1.25 true 3.01,1.5 3.323,1.25 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.052 4.281,1.25 0.458,0.198 10 false M56 3.365,1.51 3.698,1.719 0.333,0.208 10 true GND 2.771,1.51 3.219,1.708 0.448,0.198 10 true SMRG 2.281,0.156 2.552,0.313 0.271,0.156 10 true k3 1.229,0.135 1.5,0.302 0.271,0.167 10 true z9 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z9-1 (-) - k3-1 (CEI) Auxiliary battery voltage not applied between terminals M56-4 (SMRG) and M56-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M56-4 (SMRG) and M56-3 (GND) Below 1 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M56-4 (SMRG) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 25.0 to 59.0 Ω


If the result is not as specified, replace the HV battery junction block assembly.



c.

Inspect SMRP:

i.

Measure the resistance according to the value(s) in the table below.

C384277C39
3.76,1.031 4.115,1.24 0.354,0.208 2.219,0.104 2.583,0.344 0.365,0.24 1.167,0.115 1.531,0.323 0.365,0.208 3.125,1.406 3.396,1.24 true 3.781,1.417 3.531,1.25 true 2.063,1.063 2.396,0.677 true 0.833,0.854 1.344,0.656 true 0.573,0.146 0.885,0.302 0.313,0.156 10 false *a 3.823,1.052 4.281,1.25 0.458,0.198 10 false M56 2.958,1.448 3.292,1.656 0.333,0.208 10 true GND 3.667,1.458 4.115,1.656 0.448,0.198 10 true SMRP 2.281,0.146 2.552,0.302 0.271,0.156 10 true k3 1.26,0.135 1.531,0.302 0.271,0.167 10 true z9 1.813,1 2.188,1.208 0.375,0.208 10 false CEI 0.719,0.781 0.875,0.979 0.156,0.198 10 false -
*a Component without harness connected
(HV Battery Junction Block Assembly)
- -


Standard Resistance:
Tester Connection Condition Specified Condition
z9-1 (-) - k3-1 (CEI) Auxiliary battery voltage not applied between terminals M56-2 (SMRP) and M56-3 (GND) 10 kΩ or higher
Auxiliary battery voltage applied between terminals M56-2 (SMRP) and M56-3 (GND) 24.3 to 29.7 Ω



ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
M56-2 (SMRP) - M56-3 (GND) -40 to 80°C (-40 to 176°F) 140 to 290 Ω


If the result is not as specified, replace the HV battery junction block assembly.