85910X
1.INSPECT MIR HTR RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
If the result is not as specified, replace the MIR HTR relay.
87989A
2.INSPECT MIR MTR NO. 1 RELAY (w/o Seat Heater (Rear No. 1 Seat))
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Battery voltage not applied between terminals | Below 1 Ω |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the MIR MTR NO. 1 relay.
87989B
3.INSPECT MIR MTR NO. 2 RELAY (w/o Seat Heater (Rear No. 1 Seat))
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 4 | Battery voltage not applied between terminals | Below 1 Ω |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals | 10 kΩ or higher |
| 4 - 5 | Always | 10 kΩ or higher |
If the result is not as specified, replace the MIR MTR NO. 2 relay.