DATA LIST
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Air Conditioner
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Room temp. sensor (cooler thermistor) | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | Room temp. sensor (cooler thermistor) circuit malfunction
·
When open circuit: -6.50°C (20.30°F) ·
When short circuit: 57.25°C (135.05°F) |
| Ambient Temp Sensor | Ambient temp. sensor (thermistor assembly) | Min.: -23.30°C (-9.94°F)
Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Ambient temp. sensor (thermistor assembly) circuit malfunction
·
When open circuit: -23.30°C (-9.94°F) ·
When short circuit: 65.95°C (150.71°F) |
| Adjusted Ambient Temp | Adjusted ambient temperature | Min.: -30.80°C (-23.44°F)
Max.: 50.80°C (123.44°F) |
Adjust ambient temperature displayed | Air conditioning amplifier assembly circuit malfunction |
| Evaporator Fin Thermistor | Evaporator temp. sensor (No. 1 cooler thermistor) | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction
·
When open circuit: -29.70°C (-21.46°F) ·
When short circuit: 59.55°C (139.19°F) |
| Evaporator Target Temp | Evaporator target temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction
·
When open circuit: -327.68°C (-557.82°F) ·
When short circuit: 327.67°C (621.81°F) |
| Solar Sensor (D Side) | Driver side automatic light control sensor | Min.: 0
Max.: 255 |
Driver side automatic light control sensor value increases as brightness increases | Driver side automatic light control sensor circuit malfunction
·
When open circuit: 0 ·
When short circuit: 255 |
| Solar Sensor (P Side) | Front passenger side automatic light control sensor | Min.: 0
Max.: 255 |
Front passenger side automatic light control sensor value increases as brightness increases | Front passenger side automatic light control sensor circuit malfunction
·
When open circuit: 0 ·
When short circuit: 255 |
| Engine Coolant Temp | Engine coolant temperature sensor | Min.: 1.30°C (34.34°F)
Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | ·
SFI system malfunction ·
CAN communication system malfunction |
| Blower Motor Speed Level | Blower motor speed level | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | Blower motor with fan sub-assembly circuit malfunction |
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG (gauge)
Max.: 3294.37 kPaG (gauge) |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Room Temp Sensor (Rear) | No. 2 room temp. sensor (cooler thermistor) | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin (rear) temperature displayed | No. 2 room temp. sensor (cooler thermistor) circuit malfunction
·
When open circuit: -6.50°C (20.30°F) ·
When short circuit: 57.25°C (135.05°F) |
| Evap Temp Sensor (Rear) | Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) | Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F) |
Actual evaporator (rear) temperature displayed | Rear evaporator temp. sensor (No. 2 air conditioning harness assembly) circuit malfunction
·
When open circuit: -29.70°C (-21.46°F) ·
When short circuit: 59.55°C (139.19°F) |
| Blower Motor Level (Rear) | Rear blower motor control | Min.: 0
Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor (rear) speed increases | Rear blower motor control circuit malfunction |
| Air Outlet Servo Pulse (R) | Rear mode damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
·
FACE: 276 (pulse) ·
B/L: 228 (pulse) ·
FOOT: 200 (pulse) |
Rear mode damper servo sub-assembly circuit malfunction |
| Air Outlet Servo Actual Pls(R) | Rear mode damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
·
FACE: 276 (pulse) ·
B/L: 228 (pulse) ·
FOOT: 200 (pulse) |
Rear mode damper servo sub-assembly circuit malfunction |
| Air Mix Servo Targ Pulse(R) | Rear air mix damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 258 (pulse) ·
MAX HOT: 213 (pulse) |
Rear air mix damper servo sub-assembly circuit malfunction |
| Air Mix Servo Actual Pulse(R) | Rear air mix damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 258 (pulse) ·
MAX HOT: 213 (pulse) |
Rear air mix damper servo sub-assembly circuit malfunction |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction |
| Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 257 (pulse) ·
MAX HOT: 165 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) circuit malfunction |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction |
| Air Mix Servo Actual Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse | Min.: 128
Max.: 383 |
·
MAX COLD: 255 (pulse) ·
MAX HOT: 347 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) circuit malfunction |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) target pulse | Min.: 128
Max.: 383 |
·
S-FLOW: 278 (pulse) ·
FACE: 256 (pulse) ·
B/L: 245 (pulse) ·
FOOT-A: 224 (pulse) ·
FOOT-R(F): 215 (pulse) ·
FOOT-D: 207 (pulse) ·
F/D-R: 192 (pulse) ·
D/F: 173 (pulse) ·
DEF: 164 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction |
| Air Outlet Servo Actu Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) actual pulse | Min.: 128
Max.: 383 |
·
S-FLOW: 278 (pulse) ·
FACE: 256 (pulse) ·
B/L: 245 (pulse) ·
FOOT-A: 224 (pulse) ·
FOOT-R(F): 215 (pulse) ·
FOOT-D: 207 (pulse) ·
F/D-R: 192 (pulse) ·
D/F: 173 (pulse) ·
DEF: 164 (pulse) |
No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) circuit malfunction |
| Air Outlet Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) target pulse | Min.: 128
Max.: 383 |
·
S-FLOW: 234 (pulse) ·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT-A: 288 (pulse) ·
FOOT-R(F): 297 (pulse) ·
FOOT-D: 305 (pulse) ·
F/D-R: 320 (pulse) ·
D/F: 339 (pulse) ·
DEF: 348 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction |
| Air Outlet Servo Actu Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) actual pulse | Min.: 128
Max.: 383 |
·
S-FLOW: 234 (pulse) ·
FACE: 256 (pulse) ·
B/L: 267 (pulse) ·
FOOT-A: 288 (pulse) ·
FOOT-R(F): 297 (pulse) ·
FOOT-D: 305 (pulse) ·
F/D-R: 320 (pulse) ·
D/F: 339 (pulse) ·
DEF: 348 (pulse) |
No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) circuit malfunction |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly target pulse | Min.: 128
Max.: 383 |
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse | Min.: 128
Max.: 383 |
·
Recirculation: 256 (pulse) ·
Fresh: 220 (pulse) |
No. 1 blower damper servo sub-assembly circuit malfunction |
| Electric Heater Count | - | - | - | Cannot be used |
| Electric Heater Active Level | - | - | - | Cannot be used |
| Compressor Speed | Compressor speed | Min.: 0 rpm
Max.: 65535 rpm |
Actual compressor speed displayed | - |
| Compressor Target Speed | Compressor target speed | Min.: 0 rpm
Max.: 65535 rpm |
Compressor target speed displayed | - |
| Shift Set Temperature | Shift set temperature | 2C decr / 1C decr / Normal / 1C incr / 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode | Auto or Manual | Customized value displayed | - |
| Compressor Mode | Compressor mode | Auto or Manual | Customized value displayed | - |
| Noise and Vibration Reduction | Function to change the speed of the compressor when set to ON | OFF or ON | Customized value displayed | - |
| ECO MODE Cancel | Function to cancel ECO mode when set to ON | OFF or ON | Customized value displayed | - |
| ECO Switch | - | - | - | Cannot be used |
| Refrigerant Shortage Check | Refrigerant shortage check | ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control | Slow / Normal / Fast | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/defroster auto mode | ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/defroster auto blower speed increase | ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift | 3C decr / 2C decr / 1C decr / Normal / 1C incr / 2C incr / 3C incr | Customized value displayed | - |
| Compressor Drive Check | Compressor drive check | OK or NG | OK: Compressor drives
NG: Compressor does not drive |
- |
| Glass Temperature | Glass temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual glass temperature displayed | - |
| Glass Surroundings Temperature | Glass surroundings temperature | Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F) |
Actual glass surroundings temperature displayed | - |
| Glass Humidity | Glass humidity | Min.: 0%
Max.: 100% |
Actual glass humidity displayed | - |
| Refrigerant Gas Type | Refrigerant gas type | R134a or 1234yf | Refrigerant gas type displayed | - |
| FR Seat Heater Temperature | - | - | - | Although this item is displayed on the GTS, it is not applicable to the air conditioning system. |
| FL Seat Heater Temperature | - | - | - | Although this item is displayed on the GTS, it is not applicable to the air conditioning system. |
| RR Seat Heater Temperature | - | - | - | Although this item is displayed on the GTS, it is not applicable to the air conditioning system. |
| RL Seat Heater Temperature | - | - | - | Although this item is displayed on the GTS, it is not applicable to the air conditioning system. |
| Set Temperature (D Side) | Driver side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Front passenger side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Front passenger side set temperature displayed | - |
| Set Temperature (Rear) | Rear passenger side set temperature | Min.: MAX COLD
Max.: MAX HOT |
Rear passenger side set temperature displayed | - |
| Operation Limitation Control History Count (Level1) | History of auxiliary battery voltage drop in the past | Min.: 0
Max.: 255 |
Number of times auxiliary battery voltage dropped in the past displayed | ·
Counted when voltage drops below the specified level due to over discharge while driving. ·
*1 |
| Operation Limitation Control History Count (Level2) | History of auxiliary battery voltage drop in the past | Min.: 0
Max.: 255 |
Number of times auxiliary battery voltage dropped in the past displayed | ·
Counted when voltage drops below the specified level due to over discharge while driving. ·
*1 |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function | ON or OFF | Customized value displayed | - |
| S-FLOW Control Auto Function | S-FLOW control auto function | ON or OFF | Customized value displayed | - |
| Seat Blast Mode Setting | - | - | - | Although this item is displayed on the GTS, it is not applicable to the air conditioning system. |
| Number of Trouble Codes | Number of trouble codes | Min.: 0
Max.: 255 |
Number of DTCs displayed | - |
| Refrigerant High Pressure History | Refrigerant high pressure history | Min.: 0
Max.: 255 |
Number of times refrigerant high pressure history stored displayed | *2 |
*1: Refer to the following procedure to clear the A/C operation limitation history.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY
*2: Refer to the following procedure to clear the refrigerant high pressure history.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>UTILITY
Engine
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Coolant Temperature | Engine coolant temperature | Min.: -40°C (-40°F)
Max.: 140°C (284°F) |
75 to 100°C (167 to 212°F): After warming up | This is the engine coolant temperature.
|
Rain and/or Humidity Sensor
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Glass Humidity | Windshield glass humidity | Min.: 0.0%
Max.: 100.0% |
Actual windshield glass humidity is displayed | - |
| Glass Temperature | Windshield glass temperature | Min.: -30.0°C (-22°F)
Max.: 70.0°C (158°F) |
Actual windshield glass temperature is displayed | - |
| Glass Surroundings Temperature | Temperature around windshield glass | Min.: -30.0°C (-22°F)
Max.: 70.0°C (158°F) |
Actual temperature around windshield glass is displayed | - |
| Number of Trouble Code | Number of trouble codes | Min.: 0
Max.: 255 |
Number of DTCs displayed | - |
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Air Conditioner
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0
Max.: 31 |
- |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0
Max.: 7500 |
- |
| Defogger Relay (Rear) | Rear window defogger | OFF or ON | - |
| Deicer Relay (Front) | Windshield deicer | OFF or ON | - |
| Heater Active Level | - | - | - |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
Operates between 165 to 257 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
Operates between 255 to 347 pulses |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side mode) pulse | Min.: 128
Max.: 383 |
Operates between 164 to 278 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 220 to 256 pulses |
| Rear Blower Motor | Rear blower motor with fan sub-assembly | Min.: 0
Max.: 31 |
- |
| Rear Air Mix Servo Targ Pulse | Rear air mix damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 213 to 258 pulses |
| Air Outlet Servo Pulse (P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side mode) pulse | Min.: 128
Max.: 383 |
Operates between 234 to 348 pulses |
| A/O Servo Pulse(Rr D) | Rear mode damper servo sub-assembly pulse | Min.: 128
Max.: 383 |
Operates between 200 to 276 pulses |
| HWD Relay | - | - | Although this test is displayed on the GTS, it is not applicable to the air conditioning system. |
| Front Right Seat Heater | - | - | Although this test is displayed on the GTS, it is not applicable to the air conditioning system. |
| Front Left Seat Heater | - | - | Although this test is displayed on the GTS, it is not applicable to the air conditioning system. |
| Rear Right Seat Heater | - | - | Although this test is displayed on the GTS, it is not applicable to the air conditioning system. |
| Rear Left Seat Heater | - | - | Although this test is displayed on the GTS, it is not applicable to the air conditioning system. |
| Front Right Seat Blower | - | - | Although this test is displayed on the GTS, it is not applicable to the air conditioning system. |
| Front Left Seat Blower | - | - | Although this test is displayed on the GTS, it is not applicable to the air conditioning system. |
Engine
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Control the Engine Cooling Fan Duty Ratio | Control the cooling fan | 0 to 100% | Perform this test when vehicle is stopped. |