The room temp. sensor (cooler thermistor) is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the room temp. sensor (cooler thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the room temp. sensor (cooler thermistor) and reads voltage changes due to changes in the resistance of the room temp. sensor (cooler thermistor).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B1411 | Room Temperature Sensor Circuit | Open or short in room temperature sensor circuit | ·
Room temp. sensor (cooler thermistor) ·
Harness or connector ·
Air conditioning amplifier assembly |
Memorized
(4 sec. or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
If the cabin temperature is approximately -18.6°C (-1.48°F) or lower, DTC B1411 may be stored even though the system is normal.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Room Temperature Sensor | Room temp. sensor (cooler thermistor) | Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | Room temp. sensor (cooler thermistor) circuit malfunction
·
When open circuit: -6.50°C (20.30°F) ·
When short circuit: 57.25°C (135.05°F) |
| Tester Display |
|---|
| Room Temperature Sensor |
The display is as specified in the normal condition column.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>ROOM TEMPERATURE SENSOR (for Front)>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the H55 room temp. sensor (cooler thermistor) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-5 (TR) - H55-1 (+) | Always | Below 1 Ω |
| H63-3 (SG-1) - H55-2 (-) | Always | Below 1 Ω |
| H63-5 (TR) or H55-1 (+) - Other terminals and body ground | Always | 10 kΩ or higher |
| H63-3 (SG-1) or H55-2 (-) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG