Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System)
RM37A0E _58 Vehicle Interior _086896 HEATING / AIR CONDITIONING _0420833 AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  B1411  Room Temperature Sensor Circuit  


DESCRIPTION

The room temp. sensor (cooler thermistor) is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the room temp. sensor (cooler thermistor) changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the room temp. sensor (cooler thermistor) and reads voltage changes due to changes in the resistance of the room temp. sensor (cooler thermistor).

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1411 Room Temperature Sensor Circuit Open or short in room temperature sensor circuit
·

Room temp. sensor (cooler thermistor)

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized
(4 sec. or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.

HINT:

If the cabin temperature is approximately -18.6°C (-1.48°F) or lower, DTC B1411 may be stored even though the system is normal.


WIRING DIAGRAM

E432273E01
0.188,1.802 0.521,2 0.333,0.198 10 false H55 0.188,1.979 2.677,2.167 2.49,0.188 10 false Room Temp. Sensor (Cooler Thermistor) 4.635,1.792 6.938,2.073 2.302,0.281 10 false Air Conditioning Amplifier Assembly 2.146,0.667 2.323,0.885 0.177,0.219 10 false 1 2.156,1.156 2.333,1.375 0.177,0.219 10 false 2 4.5,1.073 4.656,1.26 0.156,0.188 10 false 3 4.5,0.583 4.688,0.771 0.188,0.188 10 false 5 4.823,0.667 5.073,0.854 0.25,0.188 10 false TR 4.802,1.156 5.208,1.344 0.406,0.188 10 false SG-1 5.656,0.271 5.948,0.469 0.292,0.198 11 false 5 V 6.26,0.781 6.51,0.969 0.25,0.188 10 false AD 1.906,0.667 2.063,0.865 0.156,0.198 10 false + 1.917,1.146 2.073,1.344 0.156,0.198 10 false - 4.406,0.792 4.74,0.99 0.333,0.198 10 false H63 4.406,1.271 4.74,1.469 0.333,0.198 10 false H63

PROCEDURE

1.READ VALUE USING GTS (ROOM TEMPERATURE SENSOR)
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Room temp. sensor (cooler thermistor) Min.: -6.50°C (20.30°F)
Max.: 57.25°C (135.05°F)
Actual cabin temperature displayed Room temp. sensor (cooler thermistor) circuit malfunction
·

When open circuit: -6.50°C (20.30°F)

·

When short circuit: 57.25°C (135.05°F)


Body Electrical > Air Conditioner > Data List
Tester Display
Room Temperature Sensor
50003 121 1
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.INSPECT ROOM TEMP. SENSOR (COOLER THERMISTOR)
2.INSPECT ROOM TEMP. SENSOR (COOLER THERMISTOR)

OK

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR))

NG

REPLACE ROOM TEMP. SENSOR (COOLER THERMISTOR)

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR))
a.

Disconnect the H63 air conditioning amplifier assembly connector.


b.

Disconnect the H55 room temp. sensor (cooler thermistor) connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H63-5 (TR) - H55-1 (+) Always Below 1 Ω
H63-3 (SG-1) - H55-2 (-) Always Below 1 Ω
H63-5 (TR) or H55-1 (+) - Other terminals and body ground Always 10 kΩ or higher
H63-3 (SG-1) or H55-2 (-) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG