Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System)
RM37A0E _58 Vehicle Interior _086896 HEATING / AIR CONDITIONING _0420833 AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  B1413  Evaporator Temperature Circuit or Evaporator Fin Thermistor  


DESCRIPTION

The evaporator temp. sensor (No. 1 cooler thermistor) is installed to the evaporator in the air conditioner unit to detect the temperature of the cooled air that has passed through the evaporator, which is used to control the air conditioning system. It sends signals to the air conditioning amplifier assembly. The resistance of the evaporator temp. sensor (No. 1 cooler thermistor) changes in accordance with the temperature of the cooled air that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the evaporator temp. sensor (No. 1 cooler thermistor) and reads voltage changes as the resistance of the evaporator temp. sensor (No. 1 cooler thermistor) changes. This sensor is used for frost prevention.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1413 Evaporator Temperature Circuit or Evaporator Fin Thermistor Open or short in evaporator temperature sensor circuit
·

Evaporator temp. sensor (No. 1 cooler thermistor)

·

Air conditioning harness assembly

·

Air conditioning amplifier assembly


Memorized
(4 sec. or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.

WIRING DIAGRAM

E432275E03
1.875,1.052 2.156,1.292 0.281,0.24 10 false 1 1.885,0.573 2.167,0.813 0.281,0.24 10 false 2 0.219,1.781 1.781,2.177 1.563,0.396 10 false Evaporator Temp. Sensor (No. 1 Cooler Thermistor) 2.188,1.792 4.49,2.198 2.302,0.406 10 false Air Conditioning Harness Assembly 4.615,0.792 4.938,1.021 0.323,0.229 10 false z19 4.823,1.792 7.094,2.104 2.271,0.313 10 false Air Conditioning Amplifier Assembly 4.688,0.594 4.969,0.833 0.281,0.24 10 false 6 4.688,1.063 4.969,1.302 0.281,0.24 10 false 5 5.01,0.688 5.531,0.969 0.521,0.281 10 false TE 5.01,1.167 5.479,1.417 0.469,0.25 10 false SG 5.885,0.292 6.167,0.531 0.281,0.24 10 false 5 V 6.469,0.792 6.75,1.031 0.281,0.24 10 false AD 1.865,0.781 2.333,1.031 0.469,0.25 10 false A 1.865,1.26 2.333,1.51 0.469,0.25 10 false A 4.615,1.26 4.938,1.49 0.323,0.229 10 false z19

PROCEDURE

1.READ VALUE USING GTS (EVAPORATOR FIN THERMISTOR)
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Evaporator Fin Thermistor Evaporator temp. sensor (No. 1 cooler thermistor) Min.: -29.70°C (-21.46°F)
Max.: 59.55°C (139.19°F)
Actual evaporator temperature displayed Evaporator temp. sensor (No. 1 cooler thermistor) circuit malfunction
·

When open circuit: -29.70°C (-21.46°F)

·

When short circuit: 59.55°C (139.19°F)


Body Electrical > Air Conditioner > Data List
Tester Display
Evaporator Fin Thermistor
50003 121 3
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

2.INSPECT EVAPORATOR TEMP. SENSOR (NO. 1 COOLER THERMISTOR)
2.INSPECT EVAPORATOR TEMP. SENSOR (NO. 1 COOLER THERMISTOR)

OK

3.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

NG

3.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

b.

Measure the resistance according to the value(s) in the table below.

E432366C03
1.771,0.146 2.188,0.396 0.417,0.25 4.927,0.177 5.344,0.427 0.417,0.25 1.271,1.031 1.75,1.198 true 1.938,1.208 2.448,1.01 true 1.271,0.188 1.583,0.385 0.313,0.198 10 false *a 4.458,0.167 4.771,0.365 0.313,0.198 10 false *b 1.875,0.188 2.188,0.385 0.313,0.198 10 false z19 1.021,0.938 1.51,1.156 0.49,0.219 10 false SG 2.5,0.917 2.99,1.135 0.49,0.219 10 false TE 5.094,0.219 5.406,0.417 0.313,0.198 10 false A
*a Front view of air conditioning harness assembly connector
(to Air Conditioning Amplifier Assembly)
*b Front view of air conditioning harness assembly connector
(to Evaporator Temp. Sensor (No. 1 Cooler Thermistor))


Standard Resistance:
Tester Connection Condition Specified Condition
z19-6 (TE) - A-2 Always Below 1 Ω
z19-5 (SG) - A-1 Always Below 1 Ω
z19-6 (TE) or A-2 - Other terminals and body ground Always 10 kΩ or higher
z19-5 (SG) or A-1 - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG