HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  B14B8  Refrigerant Shortage  


DESCRIPTION

This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.

The air conditioning amplifier assembly receives the ambient temperature signal, refrigerant pressure signal, etc. from various sensors.

Based on these signals, the air conditioning amplifier assembly detects the amount of refrigerant.

The A/C switch indicator is turned off and the air conditioning system is stopped if the amount of refrigerant is insufficient.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B14B8 Refrigerant Shortage The following condition is detected in the normal operation refrigerant shortage check:
Amount of refrigerant is insufficient
·

Refrigerant pipe line (leak or obstruction)

·

Cooler expansion valve

·

Air conditioning amplifier assembly

·

Harness or connector

·

Air conditioner pressure sensor


Memorized
(10 min. or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.

WIRING DIAGRAM

E432279E01
2.146,0.396 2.302,0.594 0.156,0.198 10 false 3 2.156,0.865 2.313,1.063 0.156,0.198 10 false 2 2.156,1.344 2.313,1.542 0.156,0.198 10 false 1 1.948,0.396 2.104,0.594 0.156,0.198 10 false + 1.854,0.865 2.125,1.063 0.271,0.198 10 false PR 1.958,1.323 2.115,1.521 0.156,0.198 10 false - 0.344,1.99 0.698,2.188 0.354,0.198 10 false A24 0.344,2.156 2.51,2.375 2.167,0.219 10 false Air Conditioner Pressure Sensor 4.813,1.99 7.021,2.229 2.208,0.24 10 false Air Conditioning Amplifier Assembly 4.667,0.313 4.917,0.542 0.25,0.229 10 false 11 4.698,0.792 4.917,0.99 0.219,0.198 10 false 6 4.656,1.26 4.917,1.469 0.26,0.208 10 false 15 5.01,0.875 5.385,1.063 0.375,0.188 10 false PRE 5.01,0.396 5.385,0.583 0.375,0.188 10 false S5-3 5.01,1.344 5.385,1.531 0.375,0.188 10 false SG-4 5.729,0.313 6.104,0.5 0.375,0.188 10 false 5 V 6.469,0.979 6.844,1.167 0.375,0.188 10 false AD 4.615,0.51 4.917,0.688 0.302,0.177 10 false H63 4.604,0.99 4.906,1.167 0.302,0.177 10 false H63 4.604,1.469 4.906,1.646 0.302,0.177 10 false H63

PROCEDURE

1.CHECK REFRIGERANT PRESSURE

b.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
Vehicle Condition Engine start
Doors Fully closed (windows also fully closed)
A/C Switch On
Recirculation/fresh Control Switch Recirculation
Set Temperature MAX COLD
Blower Speed HI
Air Conditioning Air Inlet Temperature 25 to 35°C (77 to 95°F)


c.

Read the manifold gauge pressure.

Standard Pressure:
Low pressure side:

150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)

High pressure side:

1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)



d.

Compare the values displayed in the Data List and on the manifold gauge.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -456.68 kPaG (gauge)
Max.: 3294.37 kPaG (gauge)
Actual refrigerant pressure displayed
·

Refrigerant line (gas leak etc.)

·

Air conditioner pressure sensor circuit malfunction


Body Electrical > Air Conditioner > Data List
Tester Display
Regulator Pressure Sensor
50003 121 51
OK:

The values displayed in the Data List and on the manifold gauge match.



Result:
Proceed to
OK
NG



OK

INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET

NG

2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - POWER SOURCE)
2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - POWER SOURCE)
a.
E432367C01
1.448,0.26 1.948,0.51 0.5,0.25 2.344,1.521 2.083,1.521 2.083,1.521 1.844,1.115 true 1.573,0.313 2.031,0.51 0.458,0.198 10 false A24 2.406,1.438 2.865,1.635 0.458,0.198 10 false + 0.625,0.292 1.083,0.49 0.458,0.198 10 false *a
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)


Disconnect the A24 air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A24-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
3.CHECK HARNESS AND CONNECTOR (AIR CONDITIONER PRESSURE SENSOR - BODY GROUND)
a.
E432367C03
1.448,0.26 1.948,0.51 0.5,0.25 1.031,1.521 1.354,1.521 1.354,1.521 1.542,1.104 true 1.573,0.313 2.031,0.51 0.458,0.198 10 false A24 0.896,1.438 1.354,1.635 0.458,0.198 10 false - 0.625,0.292 1.083,0.49 0.458,0.198 10 false *a
*a Front view of wire harness connector
(to Air Conditioner Pressure Sensor)


Disconnect the A24 air conditioner pressure sensor connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A24-1 (-) - Body ground Always Below 1 Ω



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the H63 air conditioning amplifier assembly connector.


b.

Disconnect the A24 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H63-6 (PRE) - A24-2 (PR) Always Below 1 Ω
H63-6 (PRE) or A24-2 (PR) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY (SENSOR SIGNAL CIRCUIT)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT AIR CONDITIONING AMPLIFIER ASSEMBLY (SENSOR SIGNAL CIRCUIT)
NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temp. sensor (thermistor assembly) and the evaporator temp. sensor (No. 1 cooler thermistor) to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


a.

Connect the H63 air conditioning amplifier assembly connector.


b.

Connect the A24 air conditioner pressure sensor connector.


c.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
Vehicle Condition Engine start
Doors Fully closed (windows also fully closed)
A/C Switch On
Recirculation/fresh Control Switch Recirculation
Set Temperature MAX COLD
Blower Speed HI
Air Conditioning Air Inlet Temperature 25 to 35°C (77 to 95°F)


d.

Measure the voltage according to the value(s) in the table below.

E432375C01
3.698,0.229 4.104,0.5 0.406,0.271 4.073,1.354 4.406,2.021 true 3.781,0.281 4.24,0.479 0.458,0.198 10 false H63 3.271,0.198 3.583,0.396 0.313,0.198 10 false *a 4.313,2.052 4.771,2.25 0.458,0.198 10 false PRE
*a Component with harness connected
(Air Conditioning Amplifier Assembly)
- -


Standard Voltage:
Tester Connection Condition Specified Condition
H63-6 (PRE) - Body ground
·

Engine start

·

Air conditioning system operating

·

Sensor voltage is 5V


0.74 to 4.61 V



e.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Regulator Pressure Sensor Air conditioner pressure sensor Min.: -456.68 kPaG (gauge)
Max.: 3294.37 kPaG (gauge)
Actual refrigerant pressure displayed
·

Refrigerant line (gas leak etc.)

·

Air conditioner pressure sensor circuit malfunction


Body Electrical > Air Conditioner > Data List
Tester Display
Regulator Pressure Sensor
50003 121 51
OK:

The voltage and value displayed in the Data List change.



Result:
Result Proceed to
OK A
NG (The voltage changes but the value displayed in the Data List does not change.)
NG (The voltage does not change.) B



A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the H63 air conditioning amplifier assembly connector.


b.

Disconnect the A24 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H63-15 (SG-4) - A24-1 (-) Always Below 1 Ω
H63-15 (SG-4) or A24-1 (-) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONER PRESSURE SENSOR)
a.

Disconnect the H63 air conditioning amplifier assembly connector.


b.

Disconnect the A24 air conditioner pressure sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H63-11 (S5-3) - A24-3 (+) Always Below 1 Ω
H63-11 (S5-3) or A24-3 (+) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR