The rear blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly.
If the airflow volume is low or the blower speed cannot be changed, the following factors may be the cause.
| Symptom | Factor |
|---|---|
| Airflow volume cannot be changed | ·
Air conditioning amplifier assembly malfunction ·
Rear blower motor with fan sub-assembly malfunction ·
Harness or connector |
Inspect the fuses for circuits related to this system before performing the following procedure.
Perform the Active Test according to the display on the GTS.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Rear Blower Motor | Rear blower motor with fan sub-assembly | Min.: 0
Max.: 31 |
- |
| Tester Display |
|---|
| Rear Blower Motor |
| Result | Proceed to |
|---|---|
| Rear blower motor with fan sub-assembly does not operate | A |
| Rear blower motor with fan sub-assembly operates but does not change speed | B |
A
B
| *a | Front view of wire harness connector
(to Rear Blower Motor Control) |
Disconnect the M14 rear blower motor control connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M14-1 (+B) - Body ground | Ignition switch off | 11 to 14 V |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M14-6 (GND) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REAR BLOWER MOTOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the M14 rear blower motor control connector.
Disconnect the M13 rear blower motor with fan sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M13-2 (+) - M14-2 (VM) | Always | Below 1 Ω |
| M13-1 (-) - Body ground | Always | Below 1 Ω |
| M13-2 (+) or M14-2 (VM) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the M14 rear blower motor control connector.
Disconnect the H64 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| M14-3 (SI) - H64-10 (SBLW) | Always | Below 1 Ω |
| M14-3 (SI) or H64-10 (SBLW) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the M14 rear blower motor control connector.
Connect the M13 rear blower motor with fan sub-assembly connector.
Connect the H64 air conditioning amplifier assembly connector.
Using an oscilloscope, check the waveform.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
| Item | Content |
|---|---|
| Terminal No. | H64-10 (SBLW) - H64-4 (GND2) |
| Tool Setting | 2 V/DIV., 1 ms./DIV. |
| Condition | ·
Ignition switch ON ·
Blower speed: LO |
Waveform is similar to that shown in the illustration.
The waveform varies with the blower speed.
| Proceed to |
|---|
| OK |
| NG |
OK
NG