FREEZE FRAME DATA
The motor generator control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / Rear Motor Generator / Trouble Codes.
Select a DTC in order to display its freeze frame data.
Check the freeze frame data recorded with the DTC.
| Tester Display | Measurement Item | Range |
|---|---|---|
| Engine Speed | Engine speed | Min.: 0 rpm, Max.: 16383 rpm |
| Vehicle Speed | Vehicle speed | Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) |
| Engine Run Time | Elapsed time after starting engine | Min.: 0 sec, Max.: 65535 sec |
| Warmup Cycle Cleared DTC | Warmup cycles after DTCs cleared | Min.: 0, Max.: 255 |
| Distance from DTC Cleared | Distance driven after DTCs cleared | Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) |
| Battery Voltage | Auxiliary battery voltage | Min.: 0.00 V, Max.: 16.00 V |
| Ambient Temperature | Ambient air temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Time after DTC Cleared | Time after DTCs cleared | Min.: 0 min, Max.: 65535 min |
| Hybrid/EV Battery System Voltage | HV battery voltage | Min.: 0.00 V, Max.: 1023.98 V |
| Hybrid/EV Battery System Current | HV battery current | Min.: -3276.8 A, Max.: 3276.7 A |
| Motor Revolution | Motor (MG2) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm |
| Motor Torque | Motor (MG2) torque value | Min.: -4096.000 Nm, Max.: 4095.875 Nm |
| Motor Control Mode | Motor control mode | Min.: 0, Max.: 65535 |
| Generator Revolution | Generator (MG1) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm |
| Generator Torque | Generator (MG1) torque value | Min.: -4096.000 Nm, Max.: 4095.875 Nm |
| Generator Control Mode | Generator control mode | Min.: 0, Max.: 65535 |
| VL Voltage | High voltage before it is boosted | Min.: 0.0 V, Max.: 6553.5 V |
| VH Voltage | High voltage after it is boosted | Min.: 0.0 V, Max.: 6553.5 V |
| Boosting Converter PWM Duty | Boost converter PWM duty | Min.: 0 %, Max.: 100 % |
| Boosting Converter Control Mode | Boost converter control mode | Min.: 0, Max.: 255 |
| Short Wave Highest Value | Waveform voltage in abnormal insulation detection circuit in battery voltage sensor | Min.: 0.00 V, Max.: 4.98 V |
| Fail Safe Mode | Fail safe mode | Min.: -128, Max.: 127 |
| Accelerator Position | Accelerator pedal opening angle | Min.: 0.0 %, Max.: 100.0 % |
| WIN Control Limit Power | Charge control wattage sent from battery voltage sensor to hybrid vehicle control ECU | Min.: -327.68 kW, Max.: 327.67 kW |
| WOUT Control Limit Power | Discharge control wattage sent from battery voltage sensor to hybrid vehicle control ECU | Min.: -327.68 kW, Max.: 327.67 kW |
| Rear Motor Resolver After Offset | Rear motor resolver after offset | Min.: 0.000 deg, Max.: 358.593 deg |
| Rear Motor Revolution | Rear motor (MGR) speed (detected by resolver sensor) | Min.: -32768 rpm, Max.: 32767 rpm |
| Rear Motor Torque | Rear motor (MGR) torque value | Min.: -4096.000 Nm, Max.: 4095.875 Nm |
| Rear Motor Control Mode | Rear motor control mode | Min.: 0, Max.: 65535 |
| Rear Motor Carrier Frequency | Rear motor carrier frequency | Min.: 0, Max.: 255 |
| Rear Motor Inverter Shut Down Signal | Rear motor inverter shutdown signal | Min.: 0, Max.: 255 |
| Rear Motor Inverter Temperature | Rear motor inverter temperature | Min.: 0°C (32°F), Max.: 150°C (302°F) |
| Rear Motor Temperature | Rear motor (MGR) temperature | Min.: -40°C (-40°F), Max.: 215°C (419°F) |
| Emergency Shutdown Signal | Inverter emergency shutdown | ON or OFF |
| Ready ON Status | State of system (READY) | ON or OFF |
| SMR Status | SMR status | ON or OFF |
| Generator Inverter High Current(GFINV) | Generator (MG1) inverter high current | ON or OFF |
| Generator Inverter Shut Down Status | Generator (MG1) inverter shutdown status | ON or OFF |
| Motor Inverter High Current(MFINV) | Motor inverter high current | ON or OFF |
| Motor Inverter Shut Down Status | Motor inverter shutdown status | ON or OFF |
| Boosting Converter Input High Voltage | Boost converter input high voltage | ON or OFF |
| Boosting Converter Input High Current(CFINV) | Boost converter input high current | ON or OFF |
| Boosting Converter Shut Down Status | Boost converter shutdown status | ON or OFF |
| Rear Inverter Input High Current (RFINV) | Rear inverter input high current | ON or OFF |
| Rear Inverter Shut Down Status | Rear inverter shutdown status | ON or OFF |
| Total Distance Traveled | Drive total distance | Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) |
| Total Distance Traveled - Unit | Drive total distance unit | km or mile |
| Rear Motor Resolver Offset Value | Rear motor resolver offset value | Min.: -250.000 deg, Max.: 249.992 deg |
| Rear Motor Resolver Offset Complete Status | Rear motor resolver learning complete status | ON or OFF |
| Rear Motor U Current (Lower Resolution) | Rear motor U phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A |
| Rear Motor V Current (Lower Resolution) | Rear motor V phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A |
| Rear Motor W Current (Lower Resolution) | Rear motor W phase current (Lower resolution) | Min.: -3276.8 A, Max.: 3276.7 A |