ENGINE STOP AND START ECU
Disconnect the engine stop and start ECU connectors.
Measure the resistance and voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| A33-1 (BIN2) - Body ground | Battery | Always | 9.5 to 14 V |
| A33-2 (GND2) - Body ground | Ground | Always | Below 1 Ω |
| A33-3 (BIN1) - Body ground | Battery | Always | 9.5 to 14 V |
| A33-8 (GND1) - Body ground | Ground | Always | Below 1 Ω |
| A34-1 (+B) - Body ground | Power source of engine stop and start ECU | Ignition switch ON | 9.5 to 14 V |
| A34-6 (DGND) - Body ground | Ground | Always | Below 1 Ω |
| A34-10 (NE) - Body ground | Engine speed signal from ECM | Always | 10 kΩ or higher |
| H66-13 (CANH) - Body ground | CAN communication | Always | 200 Ω or higher |
| H66-14 (CANL) - Body ground | CAN communication | Always | 200 Ω or higher |
| H66-18 (IG2) - Body ground | Ignition switch signal | Ignition switch ON | 9.5 to 14 V |
| H66-19 (ACC) - Body ground | Ignition switch signal | Ignition switch ACC | 9.5 to 14 V |
| H66-20 (ILL) - Body ground | Headlight dimmer switch (light control switch) tail signal input | Headlight dimmer switch (light control switch) in tail or head position | 9.5 to 14 V |
| H66-21 (IG1) - Body ground | Ignition switch signal | Ignition switch ON | 9.5 to 14 V |
Reconnect the engine stop and start ECU connectors.
Measure the resistance, voltage and pulse according to the value(s) in the table below.
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
| A34-3 (BRE2) - Body ground | Ground (vacuum sensor assembly) | Always | Below 1 Ω |
| A34-7 (BNT1) - A34-6 (DGND) | Engine hood courtesy switch (hood lock assembly) signal | ·
Ignition switch ON ·
Engine stopped ·
Engine hood closed |
Below 1.5 V |
·
Ignition switch ON ·
Engine stopped ·
Engine hood open |
8 to 14 V | ||
| A34-10 (NE) - A34-6 (DGND) | Engine speed signal from ECM | Idling after engine warmed up | Pulse generation
(See waveform 1) |
| A34-13 (PB) - A34-3 (BRE2) | Vacuum sensor assembly signal | ·
Ignition switch ON ·
Absolute pressure of 40 kPa (300 mmHg, 11.8 in.Hg) applied to vacuum sensor assembly |
1.6 to 2.0 V |
·
Ignition switch ON ·
Absolute pressure of 60 kPa (450 mmHg, 17.7 in.Hg) applied to vacuum sensor assembly |
2.2 to 2.6 V | ||
·
Ignition switch ON ·
Atmospheric pressure applied to vacuum sensor assembly |
3.4 to 3.8 V | ||
| A34-14 (BRVC) - A34-6 (DGND) | Vacuum sensor assembly power supply | ·
Ignition switch ON ·
Engine stopped |
4.5 to 5.5 V |
| A34-17 (CLL) - A34-6 (DGND) | Park/Neutral position switch assembly signal | ·
Ignition switch ON ·
Shift lever not in P or N |
8 to 14 V |
·
Ignition switch ON ·
Shift lever in P or N |
Below 3.0 V | ||
| A34-19 (DON2) - A34-6 (DGND) | External backup boost converter (eco run vehicle converter assembly) signal | Engine running | Pulse generation
(see waveform 2) |
| A34-21 (STA) - A34-6 (DGND) | Starter pinion operation signal | Cranking | 6.0 V or more |
| H66-1 (IG31) - A34-6 (DGND) | Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| H66-2 (B41) - A34-6 (DGND) | Backup boost converter signal | Always | 10.5 to 16 V |
| H66-3 (IG41) - A34-6 (DGND) | Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| H66-5 (ECAN) - A34-6 (DGND) | Stop and start system cancel switch (ecorun cancel switch assembly) signal | ·
Ignition switch ON ·
Stop and start system cancel switch (ecorun cancel switch assembly) pressed |
Below 1.5 V |
·
Ignition switch ON ·
Stop and start system cancel switch (ecorun cancel switch assembly) not pressed |
8 to 14 V | ||
| H66-6 (IG11) - A34-6 (DGND) | Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| H66-8 (EGND) - A33-8 (GND1) | Oil pump with solenoid assembly directions signal | One of the following conditions is met:
·
Engine stopped by stop and start control ·
Ignition switch ON (engine not running) and Active Test [Electromagnetic Oil Pump] being performed |
Pulse generation
(See waveform 3) |
| H66-9 (EMOP) - A33-8 (GND1) | Oil pump with solenoid assembly directions signal | One of the following conditions is met:
·
Engine stopped by stop and start control ·
Ignition switch ON (engine not running) and Active Test [Electromagnetic Oil Pump] being performed |
Pulse generation
(See waveform 3) |
| H66-10 (IG12) - A34-6 (DGND) | Backup boost converter signal | Ignition switch ON | 10.5 to 16 V |
| H66-11 (B43) - A34-6 (DGND) | Backup boost converter signal | Always | 10.5 to 16 V |
| H66-12 (B42) - A34-6 (DGND) | Backup boost converter signal | Always | 10.5 to 16 V |
| H66-18 (IG2) - A34-6 (DGND) | Push start switch signal | Ignition switch ACC | Below 1 V |
| Ignition switch ON | 9.5 to 14 V | ||
| H66-19 (ACC) - A34-6 (DGND) | Push start switch signal | Ignition switch off | Below 1 V |
| Ignition switch ACC | 9.5 to 14 V | ||
| H66-21 (IG1) - A34-6 (DGND) | Push start switch signal | Ignition switch ACC | Below 1 V |
| Ignition switch ON | 9.5 to 14 V | ||
| H66-24 (AC41) - A34-6 (DGND) | Backup boost converter signal | Ignition switch ACC | 10.5 to 16 V |
| H66-25 (IL41) - A34-6 (DGND) | Backup boost converter signal | Headlight dimmer switch (light control switch) in tail or head position | 10.5 to 16 V |
Waveform 1
| Item | Content |
|---|---|
| Tester Connection | A34-10 (NE) - A34-6 (DGND) |
| Tool Setting | 5 V/DIV., 2 ms./DIV. |
| Condition | Idling after engine warmed up |
Waveform 2
| Item | Content |
|---|---|
| Tester Connection | A34-19 (DON2) - A34-6 (DGND) |
| Tool Setting | 5 V/DIV., 2 ms./DIV. |
| Condition | Engine running |
Waveform 3
| Item | Content |
|---|---|
| Tester Connection | H66-8 (EGND) - A33-8 (GND1)
H66-9 (EMOP) - A33-8 (GND1) |
| Tool Setting | 10 V/DIV., 20 ms./DIV. |
| Condition | One of the following conditions is met:
·
Engine stopped by stop and start control ·
Ignition switch ON (engine not running) and Active Test [Electromagnetic Oil Pump] being performed |