Home › General › MAINTENANCE › 2GR-FKS BATTERY › from 2020.11
RM37A0E _V1 General _086848 MAINTENANCE _0419974 2GR-FKS BATTERY A

MAINTENANCE  2GR-FKS BATTERY  INSTALLATION  


PROCEDURE

Hide 1.INSTALL BATTERY

a.

Install the battery to the vehicle.


b.
A454730

Install the No. 2 battery clamp to the battery clamp sub-assembly with the bolt.

Torque:
18.5 N*m (189 kgf*cm, 14 ft.*lbf)


c.

Connect the cable to the positive (+) battery terminal and tighten the nut.

Torque:
5.0 N*m (51 kgf*cm, 44 in.*lbf)


d.

Engage the 2 claws to install the battery terminal cap to the positive (+) battery terminal.


Hide 2.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

a.
A454725C03
0.031,0.292 0.344,0.531 0.313,0.24 12 true *A 0.031,2.625 0.344,2.865 0.313,0.24 12 true *B
*A w/ Stop and Start System
*B w/o Stop and Start System


Connect the cable to the negative (-) battery terminal and tighten the nut.

Torque:
w/ Stop and Start System: : 5.4 N*m (55 kgf*cm, 48 in.*lbf)
w/o Stop and Start System: : 5.0 N*m (51 kgf*cm, 44 in.*lbf)

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION