The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during mobile phone battery removal/installation are shown below.
1. PRECAUTION (for ERA-GLONASS)
2. PRECAUTION (for eCall)
86740
3.REMOVE TELEMATICS TRANSCEIVER (for ERA-GLONASS)
86725
4.REMOVE MOBILE PHONE BATTERY (for ERA-GLONASS)
|
Remove in this Direction (1) |
|
Remove in this Direction (2) |
Loosen the 2 screws.
The 2 screws cannot be removed because they are integrated into the battery cover sub-assembly.
Disengage the 2 claws and 3 guides as shown in the illustration to remove the battery cover sub-assembly.
Lift the battery, disconnect the connector and remove the battery as shown in the illustration.
|
Remove in this Direction (1) |
|
Remove in this Direction (2) |
5.REMOVE TELEMATICS TRANSCEIVER WITH BRACKET (for eCall)
86725
6.REMOVE MOBILE PHONE BATTERY (for eCall)
Disengage the 4 claws to remove the transceiver cover.
|
Remove in this Direction |
Disconnect the connector.
Remove the mobile phone battery as shown in the illustration.