Home › Power Source / Network › 2GR-FKS (BATTERY / CHARGING) › CHARGING SYSTEM (w/ Stop And Start System) › from 2020.11
RM37A0E _57 Power Source / Network _086881 2GR-FKS BATTERY / CHARGING _0452458 CHARGING SYSTEM(w/ Stop And Start System) L

2GR-FKS BATTERY / CHARGING  CHARGING SYSTEM(w/ Stop And Start System)  PRECAUTION  


INITIALIZATION


NOTICE:
·

Make sure to perform the necessary procedures (adjustment, calibration, initialization, or registration) after parts related to the charging system have been removed/installed or replaced, or the cable has been disconnected from the negative (-) battery terminal.

(a)

When parts related to the charging system have been removed/installed or replaced:

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION

(b)

When the negative (-) battery terminal has been disconnected:

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION





HINT:

After charging the battery, perform the integrated current value initialization.

Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION


CHARGING SYSTEM PRECAUTION



NOTICE:
·

Check that the battery cables are connected to the correct terminals.

·

Disconnect the battery cables when the battery is given a quick charge.

·

Do not perform tests with a high voltage insulation resistance tester.

·

Never disconnect the battery cables while the engine is running.

·

Check that the charging cable nuts are tightened on terminal B of the generator assembly and on the No. 1 engine room relay block and No. 1 junction block assembly.