CHECK MOBILE WIRELESS CHARGER CRADLE
| Terminal No. (Symbol) | Terminal Description | Condition | Specified Condition |
|---|---|---|---|
|
*1: When the ignition switch is turned from off to ACC, the mobile wireless charger cradle monitors the charging suspension signal for 5 seconds. If the charging suspension signal is not 4 V or more for 0.8 seconds or more during monitoring, the mobile wireless charger cradle determines that there is an open in the charging suspension signal line, blinks (pattern 1) the indicator light (amber), and prohibits operation until the ignition switch is turned from off to ACC again. *2: For details about conditions when the certification ECU (smart key ECU assembly) sends the charging suspension signal, refer to System Description. |
|||
| T9-1 (PGND) - Body ground | Ground | Always | Below 1 V |
| T9-5 (ACC) - T9-1 (PGND) | Power source (ACC) | Ignition switch ACC | 11 to 14 V |
| Ignition switch off | Below 1 V | ||
| T9-6 (B+) - T9-1 (PGND) | Power source (+B) | Ignition switch off | 11 to 14 V |
| T9-7 (DIS) - Body ground | Charging suspension signal | For 5 seconds after turning ignition switch from off to ACC*1 | 4.5 to 6.0 V |
| Device being charged | Below 1 V | ||
| Charging suspended due to smart key system status*2 | 4.5 to 6.0 V | ||
| T9-10 (TAIL) - Body ground | Illumination signal | Taillight off | Below 1 V |
| Ignition switch off, taillight on | 11 to 14 V | ||