This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.
The air conditioning amplifier assembly receives the ambient temperature signal, refrigerant pressure signal, etc. from various sensors.
Based on these signals, the air conditioning amplifier assembly detects the amount of refrigerant.
The A/C switch indicator is turned off and the air conditioning system is stopped if the amount of refrigerant is insufficient.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B14B8 | Refrigerant Shortage | The following condition is detected in the normal operation refrigerant shortage check:
Amount of refrigerant is insufficient |
·
Refrigerant pipe line (leak or obstruction) ·
Cooler expansion valve ·
Air conditioning amplifier assembly ·
Harness or connector ·
Air conditioner pressure sensor |
Memorized
(10 min. or more)* |
*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.
Install a manifold gauge set.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>ON-VEHICLE INSPECTION
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle Condition | Engine start |
| Doors | Fully closed (windows also fully closed) |
| A/C Switch | On |
| Recirculation/fresh Control Switch | Recirculation |
| Set Temperature | MAX COLD |
| Blower Speed | HI |
| Air Conditioning Air Inlet Temperature | 25 to 35°C (77 to 95°F) |
Read the manifold gauge pressure.
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
Compare the values displayed in the Data List and on the manifold gauge.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG (gauge)
Max.: 3294.37 kPaG (gauge) |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
The values displayed in the Data List and on the manifold gauge match.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the A24 air conditioner pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-3 (+) - Body ground | Ignition switch ON | 4.75 to 5.25 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Air Conditioner Pressure Sensor) |
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-1 (-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-6 (PRE) - A24-2 (PR) | Always | Below 1 Ω |
| H63-6 (PRE) or A24-2 (PR) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.
It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temp. sensor (thermistor assembly) and the evaporator temp. sensor (No. 1 cooler thermistor) to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
Connect the H63 air conditioning amplifier assembly connector.
Connect the A24 air conditioner pressure sensor connector.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle Condition | Engine start |
| Doors | Fully closed (windows also fully closed) |
| A/C Switch | On |
| Recirculation/fresh Control Switch | Recirculation |
| Set Temperature | MAX COLD |
| Blower Speed | HI |
| Air Conditioning Air Inlet Temperature | 25 to 35°C (77 to 95°F) |
Measure the voltage according to the value(s) in the table below.
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
- | - |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-6 (PRE) - Body ground | ·
Engine start ·
Air conditioning system operating ·
Sensor voltage is 5V |
0.74 to 4.61 V |
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -456.68 kPaG (gauge)
Max.: 3294.37 kPaG (gauge) |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor circuit malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
The voltage and value displayed in the Data List change.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The voltage changes but the value displayed in the Data List does not change.) | |
| NG (The voltage does not change.) | B |
A
B
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-15 (SG-4) - A24-1 (-) | Always | Below 1 Ω |
| H63-15 (SG-4) or A24-1 (-) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the H63 air conditioning amplifier assembly connector.
Disconnect the A24 air conditioner pressure sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H63-11 (S5-3) - A24-3 (+) | Always | Below 1 Ω |
| H63-11 (S5-3) or A24-3 (+) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG